Released 06/2010
E-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
DECO 2000
1-51
1 4. S E T T I N G - U P P R O C E D U R E F O R F E E D D O G S E N S O R A N D F L A G
Ensure 0,8 mm gap between feed dog sensor and assembly. Sensor cable harness connector must be fitted
into SK 3 on main card. Check correct mains voltage setting is selected. Switch on machine.
Pull the handwheel round by hand keeping an eye on feed dog as feed dog goes below throat plate - stop.
Adjust flag assembly next to feed dog sensor so small red L.E.D. just comes on.
Tighten flag and sensor maintaining 8 mm gap.
E - STANDARD MACHINE ADJUSTMENT