44
10 COUPLING / DECOUPLING NETWORKS
These CDN 3153-S63 is fully automatic controlled, featuring plug and play technology - just connect
them to the NSG 3150 and they will auto detect and auto configure at system power up, available
coupling possibilities will show up in respective test windows.
All CDN 3153-S63 feature:
Manual and programmable control of EUT power ON / OFF
Input phase rotation detection (CDN 3153-S63 only)
Thermal monitoring of internal backfilter chokes; in case the EUT current goes up, the
integrated fans, which are still in standby mode and at low EUT currents, will speed up to
improve cooling.
In case of intentional or unintentional overloading, the CDN 3153-S63 will automatically
switch off EUT power, in order to protect itself (risk of fi re).
10.1 CDN 3153-S63
NSG 3150 on top of CDN 3153-S63
Technical specifications:
Voltage ratings:
400 VAC - phase to neutral or phase to ground
690 VAC - phase(s) to phase(s)
up to 1000 VDC - full current range (only with optional INA 3151-63)