43
9
TECHNICAL DATA
Parameter
Value
Pulse voltage (open circuit):
± 500 V to 15.0 kV (in 1 V steps)
Pulse current (short circuit):
± 250 A to 7.5 kA
Impedance:
2 / 12 Ω
Polarity:
Positive / negative / alternate
Phase synchronization:
Asynchronous, synchronous 0° to 359º (in 1º steps)
Coupling:
IEC / external / manual
Pulse repetition:
10* .... 600 s (in 1 sec steps) 1 .... 10 min.
500 V
– 4400 V
10 s @ positive, negative
20 s alternate
4401 V
– 8000 V
20 s
8001 V
– 12000 V
35 s
12001 V
– 15000 V
50 s
Test duration:
1 to 9999 pulses, Continuous
Instrument supply
85 to 265 VAC, 50 / 60 Hz (max. 3.15 A)
Fuse
3.15 A slow blow
Mechanical
Dimension (W x H x D)
554 mm x 257 mm x 500 mm
Weight
44 kg
Environment
Temperature
10 °C to 40 °C
Humidity
30 % to 78 %, non condensing
Atmospheric pressure
86 kPa (860 mbar) to 106 kPa (1,060 mbar)
Operating in high altitude
At lower atmospheric pressure, the user has to respect the reduced withstand
voltage of the air. The user must reduce the maximun charging voltage.