          UPS + Isolation                        User Manual 

   

© 2020 AMETEK Electronic Systems Protection | Technical Support: 1-800-645-9721 | surgex.com

                                                                                                            

   

                    

 

                               

   

                    

 

 

 

Model #: ABCE2202-11R / Part #: UPS-2200-Li-ISO 

Rack Mount UPS Specifications

 

 

 

Front  Panel  Controls  

-20 to 60

C (-40  to 140

0  

F) Shipment/ 

    

Power  On/Off  

Storage 

    

Test  

    

Humidity:  

5 to 90%  Non-Condensing (Operating, 

    

Load Level  LED  Gauge  

Shipment/Storage) 

    

Battery  Charge  LED  Gauge  

    

Altitude:  

3,000m  (10,000  ft) max.  Operating; 

12,000m  (40,000  ft) max.  Shipment/Storage. 

    

Voltage  Manager  Boost  LED 

    

Voltage  Output  On LED  

Safety  Agency  and EMC  Compliance:

 

    

Voltage  Manager  Buck  LED  

All Units  are Listed  by UL and Marked  with the UL/cUL  Marking. 

    

On Battery  LED  

Standard  UPS:

 

    

Replace  Battery  LED  

Products  Listed  To:

 

    

Overload  LED  

  

UL1778  5th Edition 

    

Fault  Code LED  

  

CSA  22.2  Nos.  107.3-14 

    

System  Over  Temperature LED 

Products  in compliance  with:

 

Rear Panel  Information  and  Controls  

    

FCC-Part  15, Subpart  B, Sections  15.107b  & 15.109b 

    

6 Foot Power  Cord  with  NEMA  L5-30P  Plug  

Class  A Digital  Device* 

    

Configuration Manager  DIP Switches  

    

CISPR11:2009, A1; 2010,  Class  A* 

    

Communications Manager  DB9  Port,  USB  Port  

    

IEC61000-4-2, Electrostatic  Discharge 

    

Circuit  Breaker  

    

IEC61000-4-3, Radiated  Electromagnetic Field  Immunity 

    

AC Inlet  Module  

    

IEC61000-4-4, Electrical  Fast  Transient/Burst Immunity 

  

SNMP  Slot  (Contact  Factory)  

    

IEC61000-4-5, Surge  Immunity 

    

IEC61000-4-6, Immunity  to Conducted  Radio  Frequency 

Internal  Batteries  

Disturbances 

    

User  Hot-Swappable (See Instruction  Manual)  

    

IEC61000-4-8, Power  Frequency  Magnetic  Field  Immunity 

    

Type:  12 Volt,  High  Rate 23W  

    

IEC61000-4-11, Voltage  Dips, Short  Interruptions, and 

    

Quantity:  8 Batteries  

Voltage  Variations 

    

Recharge  Time:  8 Hours  to 80%,  24 Hours  to Full Charge 

*

Note:  Class  B is Available  as an Option

 

Environmental 

Please  Consult  Your  SurgeX  Sales  Representative

 

    

Temperature: 0 - +40

0  

C (32 to 104

0

F)  Operating 

 

2200VA   TYPICAL  RUN-TIMES  (MINs)

 

 

 

10% (198W) 

20% 

(396W) 

 

30% (594W) 

40% 

(792W) 

 

50% (990W) 

60% 

(1188W) 

70% 

(1386W) 

80% 

(1584W) 

 

90% (1782W) 

100% 

(1980W) 

 Internal  Batteries  Only 

95 

45 

30 

19 

14 

10.5 

6.5 

5.5 

4.5      

 Internal  + 1) E4804-12 

281 

135 

85 

59 

42 

32.5 

23 

19 

14.5 

12 

 Internal  + 2) E4804-12 

467 

225 

140 

99 

70 

54.5 

38 

31.5 

23.5 

19.5 

 Internal  + 3) E4804-12 

653 

315 

195 

139 

98 

76.5 

53 

44 

32.5 

27 

 Internal  + 4) E4804-12 

839 

405 

250 

179 

126 

98.5 

68 

56.5 

41.5 

34.5 

 Internal  + 5) E4804-12 

1025 

495 

305 

219 

154 

120.5 

83 

69 

50.5 

42 

 Internal  + 6) E4804-12 

1211 

585 

360 

259 

182 

142.5 

98 

81.5 

59.5 

49.5 

 Internal  + 7) E4804-12 

1397 

675 

415 

299 

210 

164.5 

113 

94 

68.5 

57 

 Internal  + 8) E4804-12 

1583 

765 

470 

339 

238 

186.5 

128 

106.5 

77.5 

64.5 

NOISE  REJECTION-ISOLATION: 

With  unit  under  power and  an  ANSI/IEEE  C62.41Cat. A pulse  applied  either  normal  or  common mode at the input,  the noise output 

voltage will be less than 10V  normal  mode  and less than  0.5V  common mode in all four quadrants (CM-NM,  NM- NM,  CM-CM, NM-COM). 

 

SURGE  VOLTAGE  WITHSTAND CAPABILITY: 

Tested  under  power  to  ANSI/IEEE  C62.41  Cat.  A &  B (formerly IEEE587 -1980). Cat.  A - 

6000V @ 200 amps,  0.5 usec  risetime, 100 kHZ decay, Cat. B - 6000V  @ 500 amps, 0.5 usec  risetime, 100 kHZ decay. 

Warranty/Support:  

SURGEX  w warrants  the electronics  and  transformers  used  in its  unin terrup tible power managers  to be free fro m defects  in materials  and 

workmanship for a period  of five years  from  the date  of shipment.   Batteries  are warranted  for a period  of two years  from the date of shipment.  For service  or support  on any 

SURGEX product, please contact  SURGEX Technical Support at (800)  645-9721 or visit  the SURGEX website at 

www.surgex.com

 

Battery  Life Disclaimer

:  

SURGEX’s

 standard  battery  warranty  applies  only to UPS  and UPS  products  which  are continuously  connected  to AC mains  power,  except   during 

utility  power  outages.  Products  which  are regularly  and intentionally  disconnected from  AC mains  power  will experience  battery  discharge/charge cycles  potentially  far more 
numerous  than those  for which  the battery  was  designed.  As a result,  products used  in such applications  will experience  substantially  reduced  battery  life. For that reason, 

SURGEX’s

 standard  battery  warranty  does  not apply  for applications  in which  the UPS  or UPS  product  is regularly  and intentionally  disconnected from  AC mains  power. 

SURGEX  UPS  and UPS  products  used  in such  applications  shall  receive  a 90 day warranty  on batteries. 

Summary of Contents for SurgeX UPS-1440-Li-ISO

Page 1: ...UPS Isolation Transformer Battery Backup UPS 1440 Li ISO UPS 2200 Li ISO UPS 3000 Li ISO 2020 AMETEK Electronic Systems Protection 1 800 645 9721 surgex com A01 00147 Rev A...

Page 2: ...TABLE OF CONTENTS 1 0 Safety Instructions 3 2 0 Installation 7 3 0 Operation 12 4 0 Maintenance 17 5 0 Troubleshooting 22 6 0 Specifications 23...

Page 3: ...also occur Attention The attention warning symbol is used to indicate situations and conditions that can cause operator injury and or equipment damage Other warning symbols may appear along with the D...

Page 4: ...UPS Isolation Transformer User Manual 2020 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 2 Alternating Current Refer to instruction manual booklet Two person lift...

Page 5: ...teries used by SurgeX The batteries used in this UPS are sealed lead acid and are maintenance free Proper disposal of batteries is required Refer to your local codes for disposal of batteries UPS Rati...

Page 6: ...The UPS is CLASS 1 equipment Do not attempt to power the UPS from any receptacle except a properly grounded receptacle that matches the input plug provided with the UPS Do not place the UPS near wate...

Page 7: ...ck connectors when maintenance or service work inside the UPS is necessary The battery should be disconnected from the UPS by unplugging at its quick connectors when maintenance or service work inside...

Page 8: ...used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equi...

Page 9: ...tart Guide This unit is shipped with the internal batteries disconnected Before starting the UPS please follow these battery connection instructions 1 Remove UPS from the box Some units may require 2...

Page 10: ...UPS Isolation Transformer User Manual 2020 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com 8...

Page 11: ...nit 2 Carefully lift the unit out of the outer carton 3 Store the carton for future use Place the unit in a protectedarea that has adequate airflow and is free of humidity flammable gas and corrosion...

Page 12: ...inets attach 1 angled mounting bracket to each side of the UPM and or each side of the battery cabinet using the 8 screws provided 6 For 4U UPMs attach 2 angled mounting brackets to each side of the U...

Page 13: ...erials for the carrier or place of purchase and file a claim for shipping damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to...

Page 14: ...will cold start the UPS on its internal battery with no incoming AC present When the UPS is on pressing the On Off button for more than 2 seconds will turn off the UPS output power Test Silence Butto...

Page 15: ...ly The SF symbol will be displayed on the front panel of the UPS if it is connected to an improperly wiredAC receptacle This is to indicate a missing safety ground wire or a reversal in phase and neut...

Page 16: ...roperly connected and initially checked turn on the UPS by pressing and holding the front panel On Off switch for 3 seconds Operational Tests Observe the front panel of the UPS The following table sho...

Page 17: ...powered off perform an initial test of the UPS backup function by pressing the Test Silence button on the front panel During this test the Battery LED on the front panel should briefly illuminate It...

Page 18: ...utilizing MopUPS Pro software you can configure the system to automatically self test periodically The UPS is shipped with a charged battery but some discharge naturally occurs during storage and ship...

Page 19: ...te which makes it possible to use them in any physical orientation The batteries are designed to last from two to five years Their actual life span will depend on several factors including how often p...

Page 20: ...r serviceable non medical units only The battery compartment is accessed by removing the front panel as described in the following instructions No other user serviceable parts are contained in this UP...

Page 21: ...m The UPS allows the battery to be hot swapped while the system is running NOTE Changing the batteries in this UPS is designed to be a safe and simple procedure Batteries may be replaced while the UPS...

Page 22: ...a risk of electrical shock and high short circuit current The following precautions should be observed when working with batteries Remove watches rings or other metal objects Use tools with insulated...

Page 23: ...20 AMETEK Electronic Systems Protection Technical Support 1 800 645 9721 surgex com UPS Battery Replacement Instructions 1440 VA See Instructions for Returning a Depleted Battery Pack for instructions...

Page 24: ...er cord is not plugged in 4 Rear panel circuit breaker is tripped 1 Press and hold the On Off switch for 3 seconds min 2 Check wall socket and test for proper line voltage 3 Plug in input power cord 4...

Page 25: ...tive Load 4 On Battery Online Efficiency w o Charger 92 Input Voltage 120 Input Current 12 0 Amps Input Voltage Range w o Using Battery 96 to 144 Volts Output Voltage 120 Output Current VA Watts 12 0...

Page 26: ...518W 50 648W 60 778W 70 907W 80 1036W 90 1166W 100 1296W Internal Batteries Only 90 38 20 12 9 6 5 4 2 8 2 5 Internal 1 E4804 12 480 183 110 72 59 51 35 30 25 8 24 5 Internal 2 E4804 12 870 328 200 1...

Page 27: ...ve Load 4 On Battery Online Efficiency w o Charger 95 Input Voltage 120 Input Current 24 0 Amps Output Voltage 120 Output Current VA Watts 18 5 16 5 Amps Input Voltage Range w o Using Battery 96 to 14...

Page 28: ...1 E4804 12 281 135 85 59 42 32 5 23 19 14 5 12 Internal 2 E4804 12 467 225 140 99 70 54 5 38 31 5 23 5 19 5 Internal 3 E4804 12 653 315 195 139 98 76 5 53 44 32 5 27 Internal 4 E4804 12 839 405 250 17...

Page 29: ...attery Online Efficiency w o Charger 95 Input Voltage 208 Input Current 16 0 Amps Output Voltage 230 and 115 Output Current VA Watts 12 0 11 5 and 24 0 21 6 Amps Input Voltage Range w o Using Battery...

Page 30: ...58 20 14 10 7 6 4 8 3 2 3 Internal 1 E4804 12 239 178 62 42 30 24 16 10 8 9 2 7 5 Internal 2 E4804 12 389 298 104 70 50 41 26 16 8 15 2 12 Internal 3 E4804 12 539 418 146 98 70 58 36 22 8 21 2 16 5 In...

Reviews: