February 2, 2011 Revised 6-8
16. BID START The temperature of the battery
TEMP sensed by the Battery Identi-
fication Module at the start of
the charge cycle (degrees C).
17. BID END TEMP The temperature of the
battery sensed by the
Battery Identification Module
at the end of the charge
cycle (degrees C).
18. BID MAX TEMP The maximum temperature of
the battery from the begin-
ning of the last charge cycle
to the beginning of this
charge cycle. This would
be the maximum temperature
recorded while the battery
was in use or being charged.
19. PRESENT TIME The present time (24 hour
format)
20. DAY OF WEEK The present day of week
(SUN through SAT).
21. AUTO EQ. TYPE The type of auto equalize
selected. The types that can be
selected are listed below:
CYC. = By cycle count (see
AUTO EQ. COUNT).
D.O.W. = By the day of week
(see AUTO EQ. DAY).
22. AUTO EQ. The number of charge cycles
Count between equalize charges
when the auto equalize function
is programmed “ON” and the
auto equalize type is set to
“COUNT”.
23. AUTO EQ. DAY The day of the week that an
equalize charge cycle is
performed when the auto
equalize function is “ON” and
the auto equalize type is set to
“DAY”.
24. AUTO EQ. Shows the auto equalize
function on or off.
Auto equalize “OFF”
Auto equalize “ON”
25. T.O.D. START Time of day start time. (24 hour
format). See START MODE.
26. DELAYED Delayed start time interval.
START (00H 00M to 23H 59M).
See START MODE.
27. BLOCK START The beginning time of the time
of day blockout function
(24 hour format). See START
MODE.
28. BLOCK END The ending time of the time of
day blockout function.
(24 hour format). See START
MODE.
29. START The start override function that
OVERRIDE allows the operator to override
any of charger start modes
(i.e. delayed start, time of day
start, or time of day blockout)
by pressing the ENTER key.
30. START MODE Shows the selected start mode
for the start of the charge cycle.
AUTO = Automatic mode
T.O.D.S. = Time of day start mode
DLY.ST. = Delay start mode
T.O.D.B.= Time of day blockout
31. FORM CYCLES The number of forming cycles
for a new battery by disabling
the low current shutdown,
and setting VT Termination
mode for the programmed
number of cycles (00 to 30).
WARNING: Enabling the Finish Cell
Forming feature will cause the charger
to continue to run for a period of time
if the battery has been disconnected
before Charge Complete or pressing
the Manual Stop key. This condition
will continue until the programmed
number of cycles have been completed.
The battery should never be disconnect-
ed while a charge is in progress.
193111-047
SCR2000 CONTROL FEATURES