![AmeriWater MediQA MDP Series Operation & Maintenance Manual Download Page 10](http://html1.mh-extra.com/html/ameriwater/mediqa-mdp-series/mediqa-mdp-series_operation-and-maintenance-manual_3043938010.webp)
9
98-0157 Rev K
Unauthorized conversion and manufacturing replacement parts
Conversion or modification of the system is only permitted with the approval of the
manufacturer. The same applies to making changes in the programming for the control
system. Original replacement parts and accessories authorized by the manufacturer
enhance safety. Use of other parts will void the warranty.
Warranty claims and liability
The buyer has a one year warranty on all equipment and parts, excluding non-durable
components (e.g., filter cartridges, reverse osmosis membranes, filter media,
consumable chemicals, etc.); provided that the system is not subject to abuse, misuse,
alteration, neglect, freezing, accident or negligence; and provided further that the
system is not damaged as the result of any unusual force of nature such as, but not
limited to, flood, hurricane, tornado, or earthquake.
The warranty covers the replacement of equipment and/or parts only. The warranty
does not cover labor charges or travel expenses resulting from the service of
equipment. The manufacturer is excused if failure to perform its warranty obligations is
the result of strikes, government regulation, materials shortages, or other
circumstances beyond its control.
To obtain warranty service, notice must be given to the manufacturer within 30 days of
the discovery of the defect.
There are no warranties on the AmeriWater system beyond those specifically described
above. All implied warranties, including any implied warranty of merchantability or of
fitness for a particular purpose are disclaimed to the extent they might extend beyond
the above periods. The sole obligation of the manufacturer under these warranties is to
replace or repair the component or part which proves to be defective within the
specified time period, and the manufacturer is not liable for consequential or incidental
damages. No dealer, agent, representative, or other person is authorized to extend or
expand the warranties expressly described above.
Some states do not allow limitations on how long an implied warranty lasts or
exclusions or limitations of incidental or consequential damage, so the limitations and
exclusions in the warranty may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights, which vary from state to state.
Manufacturer:
AmeriWater
Telephone: 1-800-535-5585
3345 Stop 8 Road
Fax:
1-937-461-1988
Dayton, OH 45414
United States of America
Summary of Contents for MediQA MDP Series
Page 70: ...69 98 0157 Rev K 10 FLOW DIAGRAMS SPH UNITS ...
Page 71: ...70 98 0157 Rev K DPH UNITS ...
Page 72: ...71 98 0157 Rev K 11 WIRING SCHEMATIC SPH UNITS ...
Page 73: ...72 98 0157 Rev K ...
Page 74: ...73 98 0157 Rev K ...
Page 75: ...74 98 0157 Rev K ...
Page 76: ...75 98 0157 Rev K ...
Page 77: ...76 98 0157 Rev K ...
Page 78: ...77 98 0157 Rev K ...
Page 79: ...78 98 0157 Rev K ...
Page 80: ...79 98 0157 Rev K DPH Units ...
Page 81: ...80 98 0157 Rev K ...
Page 82: ...81 98 0157 Rev K ...
Page 83: ...82 98 0157 Rev K ...
Page 84: ...83 98 0157 Rev K ...
Page 85: ...84 98 0157 Rev K ...
Page 86: ...85 98 0157 Rev K ...
Page 87: ...86 98 0157 Rev K ...