Analysis Parameters
(18-0037)
AM8a Instruction Manual
February 10, 2000
0037-S04.L_
4-8
4.10
DTMF/MF ANALYZE 3
This is the third of three menus used for Tone dialing analysis. These menus apply to
DTMF
,
and
MF(R1)
. This menu contains parameters used to set Tone ON and OFF time thresholds
and Guard Time.
DTMF/MF :
ANALYZE 3:
TONE ON/OFFms(min)
35 35
* 25 to 99 (1ms steps)
Alternate:
GUARDms
40
0 to 99 (1ms steps)
* min ON time setting for DTMF
= 25 ms
* min ON time setting for MF(R1)
= 35 ms
4.10.1
TONE ON/OFFms(min):
When Tone Dialing is received, the
ON
time (time the digit is
present) and
OFF
time (quiet time between digits) must be greater than the setting of
these values. If either the
ON
time or the
OFF
time exceed these settings, the Event is
flagged as an error.
4.10.2
GUARDms:
When a Tone is present, this parameter controls whether or not the AM8a
will analyze it. This
GUARD
(Tone
ON
time) time MUST be exceeded before the
AM8a will analyze it. If the Event is shorter, it will be ignored.
4.11
THRESHOLD ANALYZE
This menu controls the Tone Level and the Off Hook threshold that the AM8a will recognize.
OFF HKvdc(min)
35
2 to 60 (1 vdc steps)
THRESHOLD:
ANALYZE :
TONEdBm(min)
-30
-40 to 0 (1 dB steps)
Alternate:
4.11.1
TONEdBm(min):
When a Tone is present, this parameter determines the
LEVEL
which
must be exceeded before the AM8a will analyze it. If a Tones Level is below this
setting, the AM8a will ignore it.
Summary of Contents for AM8a
Page 1: ...MODEL AM8a PCM VF CALL ANALYZER INSTRUCTION MANUAL...
Page 13: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xii...
Page 17: ...Table of Contents 18 0037 AM8a Instruction Manual February 10 2000 0037 TOC L_ xvi...
Page 35: ...Front Panel Operation 18 0037 AM8a Instruction Manual February 10 2000 0037 S01 L_ 1 18...
Page 55: ...Emulation Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S03 L_ 3 8...
Page 65: ...Analysis Parameters 18 0037 AM8a Instruction Manual February 10 2000 0037 S04 L_ 4 10...
Page 69: ...Auto and Manual Dialing 18 0037 AM8a Instruction Manual February 10 2000 0037 S05 L_ 5 4...
Page 89: ...Meter Display 18 0037 AM8a Instruction Manual February 10 2000 0037 S06 L_ 6 20...
Page 115: ...RS232 Entries and Printouts 18 0037 AM8a Instruction Manual February 10 2000 0037 S07 L_ 7 26...
Page 125: ...Technical Specifications 18 0037 AM8a Instruction Manual February 10 2000 0037 S08 L_ 8 10...