-7 EN-
1
Mounting the SpaLet Bowl
Installation Procedure
1. Remove the open/close knob
<Floor water supply>
Wall
Water shutoff valve
Water
shutoff
valve
Open/close knob
Approx.
10°
Metal tool setting
(Hex)
Water supply inlet
100 mm
(3-15/16
"
)
280 mm
(11
"
)
Center line
of the
SpaLet
bowl
Water supply pipe
Sealing tape
<Wall water supply>
Approx.
10°
Floor
Open/close knob
Metal tool setting
(Hex)
Water supply inlet
150 mm
(5-15/16
"
)
280 mm
(11
"
)
Center line
of the toilet
bowl
Water
supply
pipe
Sealing tape
2. Affix the water shutoff valve to the
water supply pipe.
Perform this step after finishing the wall and
floor.
Attach the sealing material (sealing tapes) to
the threaded section.
* Hook the tool on the hook setting (hex) on
the water shutoff valve, and fasten it.
[See Note 2-2]
Wall water supply ··· Mount the water supply
inlet at approx. 10° downward relative to the
horizontal level.
Floor water supply ··· Mount the water
supply inlet at approx. 10° tilted to the wall.
3. Install the open/close knob
* Check that the water shutoff valve is closed.
Click
Open/close
knob
Positioning
groove
2
Attaching the water shutoff valve
[See Note 2-1]
[Note 2-1]
● Do not push or step on the water shutoff valve.
* The pipe may come loose, or the water shutoff
valve may be damaged, resulting in water
leakage.
* The wall or floor may also be damaged.
● Affix the water shutoff valve water supply inlet
in such a way that the water supply hose is not
crimped.
[Note 2-2]
● Ensure to hook the tool on the metal tool
setting (hex).
* The water shutoff valve may be damaged,
resulting in water leakage.
Metal tool setting
Resin