background image

-3 EN-

Do not attach the product to any water source 
other than potable water.
It may cause electric shock, fire and skin  
inflammation due corrosion of electronic parts 
inside the seat unit.

Do not disassemble or modify the product.
It may cause electric shock or fire.

Do not use loose outlet.
It may cause electric shock or fire.

 

CAUTION

Install a high-sensitivity, high-speed ground 
fault circuit interrupter (with a rated current 
value of 15 mA or below) on the primary side 
of the power supply.
There is a danger of electric shock.

The SpaLet

®

 bowl is made of ceramics, and 

ceramics are fragile. Note the following when 
handling the SpaLet bowl:
    ––   Prior to installation, make sure that the 

SpaLet bowl is in a good condition and  
not damaged.

    ––  After installation, check the SpaLet bowl 

for any damages.

Failure to do so may cause injury, water  
leakage and/or flooding.

Wash out foreign materials or rust inside the 
pipes before connecting the product.
Failure to do so could damage the internal 
parts of the product, which may cause water 
leakage and/or flooding.

Note the following when using the strainer:
    ––    Close the water shutoff valve when 

removing the strainer.

    ––    When installing the strainer, tighten it 

fully so there is no gap.

    ––    Check that the O-ring is free from  

foreign materials when attaching it.

If foreign materials are attached to the O-ring, 
it may cause flooding due to water leakage.

Adjust the water shutoff valve and check for 
water leakage after the installation.
It may cause water leakage and/or flooding.

   

If the water is expected to be frozen,
drain the water out from the product.
Failure to do so may cause fire, water 
leakage, and/or flooding due to damage 
from freezing.

Drain the air from the pipes after any
building construction or renovation, or 
when water supply is restored after an 
interruption.
If the water supply contains air, it may 
cause damage or malfunction to the  
product or pipes. There is a danger of  
injury or damage to the building or  
furniture due to flooding.

Summary of Contents for 8017A60GRC

Page 1: ...Procedure 1 Mounting the SpaLet Bowl 2 Attaching the Water Shutoff Valve 3 Mounting the Seat Unit 4 Connecting the Water Supply Hose Seat Unit End 5 Connecting the Water Supply Hose Water Shutoff Valve End 6 Connecting to the Power Supply 7 Positioning and Mounting the Remote Control 8 Test Operation 9 Mounting the Side Cover Installation Manual Advanced Clean 100 SpaLet Bidet Seat Model 8017A60GR...

Page 2: ...and the product could malfunction causing injury Do not connect or disconnect the power plug or socket or power cord with wet hands There is a danger of electric shock Hold the plug or socket when connecting or disconnecting the power plug or socket If the plug or socket is connected or disconnected by holding the cord there is a danger of fire or electric shock due to the plug or socket or cord b...

Page 3: ...st inside the pipes before connecting the product Failure to do so could damage the internal parts of the product which may cause water leakage and or flooding Note the following when using the strainer Close the water shutoff valve when removing the strainer When installing the strainer tighten it fully so there is no gap Check that the O ring is free from foreign materials when attaching it If f...

Page 4: ...n 375 14 3 4 min 400 15 3 4 min 2 50 2 min 1050 41 5 16 min Remote Control 280 11 700 27 9 16 min 15 9 16 min Unit mm INSTALLATION POSITION OF THE REMOTE CONTROL a b b 1300 mm 51 3 16 On the left side On the right side Install the remote control on the left wall when facing the SpaLet unit so that it is on the same side as the remote control signal receiver as far as possible If for any chance the...

Page 5: ...re and flow pressure By using a pressure measuring device it will be easy to check the installation availability of the appliance The flow pressure greatly varies depending on the peripheral conditions including piping Be sure to make water pressure measurement with the water supply pipe where the appliance is installed Hydrostatic Pressure Measuring Method Make water pressure hydrostatic pressure...

Page 6: ...er supply hose 410 mm 16 1 8 Clip gray On the SpaLet body connection side Clip white left right Side cover Attached panel Upper body sensor Remote Control Seat unit Side cover Flush button Remote control receiver SpaLet body indicator Power plug with ground fault protected Water shutoff valve Open close knob Water supply hose Points of caution Nozzle shutter Product No Nozzle for rear washing SpaL...

Page 7: ...l on the hook setting hex on the water shutoff valve and fasten it See Note 2 2 Wall water supply Mount the water supply inlet at approx 10 downward relative to the horizontal level Floor water supply Mount the water supply inlet at approx 10 tilted to the wall 3 Install the open close knob Check that the water shutoff valve is closed Click Open close knob Positioning groove 2 Attaching the water ...

Page 8: ...he SpaLet bowl The edge of the SpaLet bowl is seen Tighten the nut with the included tool Torque at 2 0 2 5 N m 20 25 kgf cm 1 48 ft lb to 1 9 ft lb 4 Remove the protective sheet from the SpaLet seat SpaLet seat protective sheet Seat unit Align the securing bolts to the bolt holes Turn 3 Mounting the Seat Unit Note 3 1 Do not remove the plate metal item Water leakage may result Note 3 2 Check that...

Page 9: ...ing installation debris may enter the water supply hose resulting in a valve malfunction Note 4 2 Take care that the O ring is not damaged If the O ring is broken or otherwise damaged water leakage may occur Attach the clip firmly Wrong Correct Note 4 3 Seat the clip firmly until it makes an audible click Water leakage may result Note 4 4 Install the clip horizontally to the side of the SpaLet bod...

Page 10: ...ck that it is attached properly Also pull the water supply hose gently to ensure that it is connected properly Click Clip white Note 5 1 Be careful not to impact the power plug or let it fall into the SpaLet bowl Note 5 2 Ensure that the water supply hose is not bent tightly or stretched Do not use a hose that has been bent The hose may be damaged resulting in water leakage This may result in inco...

Page 11: ...Confirm that the power indicator on the seat unit are illuminated Flush button indicator Power indicator WARNING Ensure the electrical outlet to which the power cord is connected is properly grounded as failure to do so may cause electric shock etc GROUND 6 Connecting to the Power Supply ...

Page 12: ...all See Note 7 2 Out of 4 slots use the outer 2 slots with A marks If the holder can be installed only with a hole pitch at 100 mm 3 15 16 use the inner 2 slots For a plywood wall 5 mm 3 16 thick Affix the holder firmly with the supplied wood screws For a plywood wall 5 mm 3 16 thick or a plaster board wall Make the pilot holes with 6 mm 1 4 diameter 5 mm 3 16 diameter for a plaster board wall Use...

Page 13: ...ess the CLEANSING button Ensure that the shower comes out from the nozzle to the palm CLEANSING 2 Does the shower stop when the STOP button is pressed Bidet nozzle 1 Does the warm water with an appropriate temperature come out from the nozzle Press the BIDET button Ensure that the shower comes out from the nozzle to the palm BIDET 2 Does the shower stop when the STOP button is pressed 3 Remove the...

Page 14: ...ence 9 1 If the water shutoff valve is located on the right when facing the SpaLet remove the attached panel attached to the right side cover and attach it to the left side cover Remove the screw on the back of the right side cover Remove the attached panel from the right side cover Remove in the direction indicated Attach the attached panel to the left side cover Insert in the direction indicated...

Page 15: ... tighten the strainer See Note 10 2 7 Attach the side cover 8 Connect the power plug to the outlet 9 Open the water shutoff valve 10 Check for leaks from the water shutoff valve If the water does not flow well clean the strainer Note 10 1 Do not remove the strainer when the water supply valve is open Water will leak from the strainer Note 10 2 When installing the strainer make sure that the water ...

Page 16: ...n NOTE Do not turn on and off the indoor equipment breaker to perform the above operation If power is turned on simultaneously for multiple bidets the receiving signal of other bidets may be changed Some signals cannot be set on some products Signal Number Operation Button Battery Mark No of Flashes Signal 1 Water Temp Once Signal 2 Seat Temp Twice Signal 3 Power save Three times Signal 0 Nozzle C...

Reviews: