background image

-5 EN-

FIRMLY FIX THE WATER SUPPLY PIPE

An impact applied to the hose due to high water pressure 

may cause vibrations.

Fix the water supply pipe firmly so that it does not loosen.

There is a danger vibration or flooding.

TECHNICAL DATA 

Rated voltage

   AC120V 50/60Hz

   Rated power consumption

   850 W (environment 68°F, water 59°F)

Max rated power consumption

   1300 W (environment 68°F, water 59°F)

Length of the power cord

   39-3/8" (1000 mm)

Length of the water supply hose

   16-1/8" (410 mm)

Waterproof grade

   IPX4

Water pressure range

   Minimum: 0.175MPa/25 PSI [hydrostatic pressure] and       

   0.10MPa/14.5 PSI (flow pressure) and 17L/min. when flowing.

   Maximum: 0.75MPa/109 PSI

Water connection cross section

   R1/2

Operating temperature range

   30°F - 104°F

Units

   V = volt, Hz = hertz, W = watt, m = meter,

   MPa =mega pascal, in = inch,

   °C = degrees Celsius, °F = degrees Fahrenheit,

   PSI = pounds square inch

   L = Liter, min. = minute

Flushing water volume

   S-trap: full 1.32 gallons, light 0.90 gallons

HOW TO CHECK WATER PRESSURE

     • When installing a flush toilet, check that the required water pressures (hydrostatic pressure and flow pressure) specified for   

       each appliance are secured.

     • If the water pressure exceeds 0.75MPa, use a pressure reducing valve before installation for use.

[Water Pressure Checks]

Hydrostatic pressure and flow pressure checks are required for installing water supply appliances. If no water shutoff valves or 

pressure measuring devices are prepared beforehand, connect the appliances as shown below to measure the hydrostatic pressure 

and flow pressure. By using a pressure measuring device, it will be easy to check the installation availability of the appliance.
The flow pressure greatly varies, depending on the peripheral conditions including piping. Be sure to make water pressure 

measurement with the water supply pipe where the appliance is installed.

[Hydrostatic Pressure Measuring Method]

Make water pressure (hydrostatic pressure) measurement in a state where valve 1 is fully opened and valve 2 is fully closed.

[Flow Pressure Measuring Method]

(1) First, check that valve 2 is fully closed and valve 1 is fully opened. Next, gradually open valve 2. Then the hydrostatic   

     pressure will gradually decrease (the flow pressure is the water pressure at the time of water supply).

(2) Adjust valve 2 so that the water pressure will set to the minimum required water pressure of the product. Then close valve 1.

(3) Empty the bucket. Then fully open valve 1 and measure the time until the water level reaches the scale of the bucket.  

      Calculate the flow rate from the bucket capacity divided by the period of time and check that the flow rate necessary for the   

      use of the product is secured.

     • If the installed appliance is used simultaneously with the water supply appliance in the kitchen, washroom, etc., the flow pressure  

       and the flow rate will decrease. In that case, measure the flow pressure in a simultaneous operating state of the appliances.

[Dedicated Pressure Measuring Device

]

Use a pressure measuring device to make hydrostatic pressure and flow pressure checks. It will be easy to check the installation 

availability of the appliance.

Water
Supply

Valve 1 for discharging 
and shutting off water

Bucket with 
scale

Pressure
Gauge

Summary of Contents for 8017A60GRC

Page 1: ...Procedure 1 Mounting the SpaLet Bowl 2 Attaching the Water Shutoff Valve 3 Mounting the Seat Unit 4 Connecting the Water Supply Hose Seat Unit End 5 Connecting the Water Supply Hose Water Shutoff Valve End 6 Connecting to the Power Supply 7 Positioning and Mounting the Remote Control 8 Test Operation 9 Mounting the Side Cover Installation Manual Advanced Clean 100 SpaLet Bidet Seat Model 8017A60GR...

Page 2: ...and the product could malfunction causing injury Do not connect or disconnect the power plug or socket or power cord with wet hands There is a danger of electric shock Hold the plug or socket when connecting or disconnecting the power plug or socket If the plug or socket is connected or disconnected by holding the cord there is a danger of fire or electric shock due to the plug or socket or cord b...

Page 3: ...st inside the pipes before connecting the product Failure to do so could damage the internal parts of the product which may cause water leakage and or flooding Note the following when using the strainer Close the water shutoff valve when removing the strainer When installing the strainer tighten it fully so there is no gap Check that the O ring is free from foreign materials when attaching it If f...

Page 4: ...n 375 14 3 4 min 400 15 3 4 min 2 50 2 min 1050 41 5 16 min Remote Control 280 11 700 27 9 16 min 15 9 16 min Unit mm INSTALLATION POSITION OF THE REMOTE CONTROL a b b 1300 mm 51 3 16 On the left side On the right side Install the remote control on the left wall when facing the SpaLet unit so that it is on the same side as the remote control signal receiver as far as possible If for any chance the...

Page 5: ...re and flow pressure By using a pressure measuring device it will be easy to check the installation availability of the appliance The flow pressure greatly varies depending on the peripheral conditions including piping Be sure to make water pressure measurement with the water supply pipe where the appliance is installed Hydrostatic Pressure Measuring Method Make water pressure hydrostatic pressure...

Page 6: ...er supply hose 410 mm 16 1 8 Clip gray On the SpaLet body connection side Clip white left right Side cover Attached panel Upper body sensor Remote Control Seat unit Side cover Flush button Remote control receiver SpaLet body indicator Power plug with ground fault protected Water shutoff valve Open close knob Water supply hose Points of caution Nozzle shutter Product No Nozzle for rear washing SpaL...

Page 7: ...l on the hook setting hex on the water shutoff valve and fasten it See Note 2 2 Wall water supply Mount the water supply inlet at approx 10 downward relative to the horizontal level Floor water supply Mount the water supply inlet at approx 10 tilted to the wall 3 Install the open close knob Check that the water shutoff valve is closed Click Open close knob Positioning groove 2 Attaching the water ...

Page 8: ...he SpaLet bowl The edge of the SpaLet bowl is seen Tighten the nut with the included tool Torque at 2 0 2 5 N m 20 25 kgf cm 1 48 ft lb to 1 9 ft lb 4 Remove the protective sheet from the SpaLet seat SpaLet seat protective sheet Seat unit Align the securing bolts to the bolt holes Turn 3 Mounting the Seat Unit Note 3 1 Do not remove the plate metal item Water leakage may result Note 3 2 Check that...

Page 9: ...ing installation debris may enter the water supply hose resulting in a valve malfunction Note 4 2 Take care that the O ring is not damaged If the O ring is broken or otherwise damaged water leakage may occur Attach the clip firmly Wrong Correct Note 4 3 Seat the clip firmly until it makes an audible click Water leakage may result Note 4 4 Install the clip horizontally to the side of the SpaLet bod...

Page 10: ...ck that it is attached properly Also pull the water supply hose gently to ensure that it is connected properly Click Clip white Note 5 1 Be careful not to impact the power plug or let it fall into the SpaLet bowl Note 5 2 Ensure that the water supply hose is not bent tightly or stretched Do not use a hose that has been bent The hose may be damaged resulting in water leakage This may result in inco...

Page 11: ...Confirm that the power indicator on the seat unit are illuminated Flush button indicator Power indicator WARNING Ensure the electrical outlet to which the power cord is connected is properly grounded as failure to do so may cause electric shock etc GROUND 6 Connecting to the Power Supply ...

Page 12: ...all See Note 7 2 Out of 4 slots use the outer 2 slots with A marks If the holder can be installed only with a hole pitch at 100 mm 3 15 16 use the inner 2 slots For a plywood wall 5 mm 3 16 thick Affix the holder firmly with the supplied wood screws For a plywood wall 5 mm 3 16 thick or a plaster board wall Make the pilot holes with 6 mm 1 4 diameter 5 mm 3 16 diameter for a plaster board wall Use...

Page 13: ...ess the CLEANSING button Ensure that the shower comes out from the nozzle to the palm CLEANSING 2 Does the shower stop when the STOP button is pressed Bidet nozzle 1 Does the warm water with an appropriate temperature come out from the nozzle Press the BIDET button Ensure that the shower comes out from the nozzle to the palm BIDET 2 Does the shower stop when the STOP button is pressed 3 Remove the...

Page 14: ...ence 9 1 If the water shutoff valve is located on the right when facing the SpaLet remove the attached panel attached to the right side cover and attach it to the left side cover Remove the screw on the back of the right side cover Remove the attached panel from the right side cover Remove in the direction indicated Attach the attached panel to the left side cover Insert in the direction indicated...

Page 15: ... tighten the strainer See Note 10 2 7 Attach the side cover 8 Connect the power plug to the outlet 9 Open the water shutoff valve 10 Check for leaks from the water shutoff valve If the water does not flow well clean the strainer Note 10 1 Do not remove the strainer when the water supply valve is open Water will leak from the strainer Note 10 2 When installing the strainer make sure that the water ...

Page 16: ...n NOTE Do not turn on and off the indoor equipment breaker to perform the above operation If power is turned on simultaneously for multiple bidets the receiving signal of other bidets may be changed Some signals cannot be set on some products Signal Number Operation Button Battery Mark No of Flashes Signal 1 Water Temp Once Signal 2 Seat Temp Twice Signal 3 Power save Three times Signal 0 Nozzle C...

Reviews: