REV. 4-6-2010
Page 6 of 11
2. Connect the pilot tubing fitting into the gas control connection and tighten. (Use caution on brass connectors) Note:
Figure #5
Wiring The Pilot
1. Connect the
“S”
&
“I”
wires from the pilot assembly to the
“S”
&
“I”
terminals on the (AF-4000 MOD) modual Note:
Figure
#6.
2. Route the
“S”
&
“I”
wires from the pilot assembly to the (AF-4000 MOD) module in an area that will be away from
the pilot or main burner flame.
Figure #5
Figure #6
Wiring The (AF-4000) Valve
1. Locate the (2) pin male connectors on the front (Face) of the AF-4000 electronic control valve Note: Figure # 7.
2. If the AF-4000 electronic control valve is eqiuped with a HI/LO solenoid, HI/LO DC motor drive, or HI/LO Step Motor
locate the wiring connections on the HI/LO device Note: Figure #8
Figure #7
Figure # 8
Wiring The (AF-4000 MOD)
Module
1. Locate the (AF-4000 MOD) module in an area that that will not exceed an ambient temperature of 150º F.
2. Locate all the connections on the (AF-4000 MOD) module Note: Figure #6.
3. Locate all the wire connections on the (8) pin connector wiring harness Note Figure #12.
Remote/Off
S
I
ADJ.
IPI
Continuous
Pilot
Off/On
POWER
Learn
AUX
(AF-4000 MOD) Module Top
6 Volt DC Adaptor
Power Connection
8 Pin IPI Connection
AUX Connection
“S” Pilot Connection
“I” Pilot Connection
H
i
Lo
Optional
Manual HI/LO
Optional
HI/LO solenoid
Optional
Veriable HI/LO
Optional
Step Motor HI/LO
(AF-4000MOT)