american flame AF-4000 Series Manual Download Page 5

 

 

 

REV. 4-6-2010   

Page 5 of 11

   

 
 
 
 

Installation of AF-4000 Control

 

 

 

 

 

 

 

 

 

 

 

 

1.  Mount control 0 to 90 degrees in any direction, from the upright position  

of the gas control knob, including vertically. 

2.  Mount the control so gas flow is in the direction of the arrow on the side  

                      Figure #2 

or back of the control. 

3.  Thread pipe 9/16 in. into the control. Do not inset deeper than 3/8 in. Valve  

distortion or malfunction can result if the pipe is inserted too deeply.   

 

4.  Apply a moderate amount of good quality pipe compound to pipe only, 

leaving two (2) end threads bare. On LP installations, use compound resistant 
to LP gas. See Figure #2 

5.  Remove plastic dust  seals over the control Inlet and Outlet if necessary. 
6.  Connect pipe to control Inlet and Outlet. Use wrench on either side of the  

pipe outlet. See Figure #3  

 
 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

Figure #3 

 

 

 

 

 

Converting the AF-4000 Natural to Propane 

 
The AF-4000 electronic control valve is convertable from natural gas to propane gas by a Simple Rotary knob located on 
the front (Face) of the valve. Note: Figure #4 
1.  Unscrew and remove the cover cap. Note: the position of the marker on the shaft of the Simple Rotary knob. This 

mark will point to NAT or LP that indicates the type of gas the valve is set on. 

2.  To convert the AF-4000 from the factory setting (NAT) push in the Simple Rotary knob and rotate 90º. Note: the 

marker will now point to LP and the shaft will stay in. 

3.  To convert the AF-4000 back to the factory setting (NAT) push in the Simple Rotary knob and rotate 90º. Note: the 

marker will now point to NAT and the shaft will stay out. 

4.  After the conversion has been made check the out let pressure with a manometer. The factory setting on the internal 

regulator is 3.50”wc natural and 10.5”wc propane. 

5.  Replace the cover cap. 

Use extreme caution when changing this Simple Rotary knob 

 

 

 
 
 
 

 
 
 
 
 
 

 

 

Figure #4 

 
 

Spark to Pilot Burner Connections 

 
This gas control uses a spark to pilot burner assembly. The pilot gas connections are as follows: 
 
1.  Select the pilot outlet on the AF-4000 valve to be used (Side or back) connection. If the side connection is used, the 

plug will need to be moved to the back pilot conection. After the plug has been installed check for leaks with rich soap 
and water solution.  

 

 

 

f i r e - p a r t s . c o m

Summary of Contents for AF-4000 Series

Page 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Page 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Page 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Page 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Page 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Page 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Page 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Page 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Page 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Page 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Page 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...

Reviews: