1.  Before lighting, smell around the appliance area for gas. If the appliance uses LP (bottled) gas, be sure to smell next 

to the floor because LP gas is heavier than air. If you smell gas, immediately shut off the manual valve in the gas 
piping to the appliance or, on LP at the tank. Do not try to light any appliance. Do not touch any electrical switch or 
use the phone. Leave the building and call your gas supplier. If your gas supplier cannot be reached, call the fire 
department. 

2.  The gas conrol must be replaced if it has been flooded with water. Call a qualified service technician. 
 
3.  The gas control is a safety device. It must be replaced in case of any physical damage such as bent terminals, 

missing parts, stripped threads, or evidence of exposure to heat. 

 

IMPORTANT:

 

Follow the operating instructions provided by the manufacturer of your heating appliance. 

 

TROUBLESHOOTING

 

 
IMPORTANT:

 

An experienced qualified service technician should perform trouble-shooting procedures. 

If the pilot will not stay lit:

 

 
1.  Confirm that the “S” wire and the “I” wire are properly connected to the (AF-4000 MOD) modual “S” and “I” terminals. 

Note: Figure #7 for terminal locations. 

2.  Confirm that the Spark to Pilot burner is properly grounded to the AF-4000 gas control valve and to the (AF-4000 

MOD) module. 

3.  Check the power sorce (1) the 6-volt power adaptor or the (AF-4000 BP) battery pack connections and condition of 

batteries. 

4.  Optional check the position of the CONTINUOUS PILOT switch on the (AF-4000 MOD) module  

 

If main burner does not come ON when the manual switch or remote control is turned ON:

 

 

1.  Confirm that the pilot sparks and lights. 
2.  Check the (2) pin plastic connectors that plug in the face of the AF-4000 gas control valve Note: Figure #6 
3.  Confirm that theAF-4000 gas control is properly grounded to the (AF-4000 MOD) module. 

 
 
 
 
 
 
 
 
 

 
 

American Flame, Inc.   9230 Conservation Way   Fort Wayne, IN  46809

 

Phone (260) 459-1703                                                                       Fax (260) 459-1592 

 

 

 

 

 

 

Limited Warranty 

 

 

American Flame, Inc. warrants the AF-4000 Valve series for 12 months from the date of purchase or installation to the original 
purchaser to be free from defects in materials and workmanship. Damage to the AF-4000 Valve caused by accident, misuse, 
abuse, or installation error, whether performed by a contractor, service company, or owner, is not covered by this warranty. 
American Flame will not be responsible for labor charges and/or damage incurred in installation, repair, replacement, or for 
incidental or consequential damage. Some states, provinces, and nations do not allow exclusion or limitations of incidental or 
consequential damages, so the above limitations or exclusions may not apply. This warranty gives you specific legal rights. You 
may also have other rights that vary by state, province, or nation.

 

 

f i r e - p a r t s . c o m

Summary of Contents for AF-4000 Series

Page 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Page 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Page 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Page 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Page 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Page 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Page 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Page 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Page 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Page 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Page 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...

Reviews: