american flame AF-4000 Series Manual Download Page 1

 

 

 

REV. 4-6-2010   

Page 1 of 11

   

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

AF-4000 Series   

  Electronic Gas Control Valve 

 
 
 
APPLICATION   

 

 

 

 

 

 

The AF-4000 Electronic Gas Control Valve is designed for use in gas in hearth products, wall mount furnaces, and space 
heating appliances. For use with Propane or natural gas. 
 

 
 
AF-4XXX MODEL IDENTIFICATION 
 
 

  A 

F        4           X           X          X  

 

 
 

 

 

 

 

 

 

 

Inlet/Outlet Configuration

 

 

 

 

 

 

 

 

 

0 = Side Inlet/ Side Outlet, 3/8” NPT

 

 

 

 

 

 

1 = Back Inlet/Side Outlet, 3/8” NPT 

 

 

 

 

 

 

 

 

2 = Side Inlet/Back Outlet, 3/8” NPT 

 

 

 

 

 

 

 

 

3 = Back inlet/ Back outlet, 3/8” NPT 

  

 

 

 

 

 

 

 

4 = Back-Side Inlet/Back-Side outlet, 3/8” NPT 

     American Flame 

 

 

 

 

 

5 = Side Inlet/Side Outlet, 1/2" NPT 

 

 

 

 

 

 

 

 

6 = Side Inlet/Outlet, 1/2" NPT, 
      Back Inlet/Outlet, 3/8”NPT   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

         

 

HI/LO Control   

 

  

 

 

 

 

 

        

0 = Manual without Hi/Lo Solenoid or Mech. Adjust. 

                                                     

 

1 = Mech. HI to LO Adjustment     

     4000 Series  

 

        

 

2 = With High/Low Solenoid (Remote)               

 

 

 

 

 

 

3 = With High/Low Variable DC Motor Drive (Remote) 

 

 

 

 

 

 

4 = With High/Low Step Motor (Model AF-4000MOT) 

 

 

 

 

 

  

 

Type of Valve 
0 = Vented Control Valve 
1 = Ventfree Control Valve

 

 

 

FEATURES 

  Multi positional (All Plans) / Versatile Mounting. 

  DC volt powered internal solenoids. 

  50,000 BTU/hr as tested by CSA per test standard with a 2” wc inlet and 1” wc outlet with 1” wc pressure drop (All 

inlet/outlet configurations). 

  AF-4000 series available with 0ºF to 175ºF (-18

0

 C to 79

0

 C) temperature range. 

  Multiple inlet/outlet connections (3/8” NPT, Optional 1/2" NPT Side Inlet and Outlet). 

  Multiple Pilot connections (Side and Back). 

  Fine mesh screens on inlets. 

  Multiple mounting holes (All 10-24 SAE threads) 

  Low profile / Compact size. 

  Easy pilot adjustment screw (Valve on the front). 

  European style inlet / outlet pressure taps (Located on the valve front). 

  Simple unique rotary conversation from natural to propane gas. 

  Vented / Vent free models available. 

A

F

A M E R I C A N   F L A M E

 

f i r e - p a r t s . c o m

Summary of Contents for AF-4000 Series

Page 1: ...ith High Low Variable DC Motor Drive Remote 4 With High Low Step Motor Model AF 4000MOT Type of Valve 0 Vented Control Valve 1 Ventfree Control Valve FEATURES Multi positional All Plans Versatile Moun...

Page 2: ...s Side Back of valve Ambient Temperature Range 0 0 F to 175 0 F 18 0 C to 79 0 C Voltage 6 Volt DC Powered Approvals CSA International Valve Report Number 224930 1546330 Module Report Number 224930 19...

Page 3: ...REV 4 6 2010 Page 3 of 11 DIMENSIONS fire parts com...

Page 4: ...hnician Force or any attempt to repair the gas control valve can result in fire or explosion Location Locate the AF 4000 gas control where it cannot be affected by steam cleaning high humidity drippin...

Page 5: ...re 4 1 Unscrew and remove the cover cap Note the position of the marker on the shaft of the Simple Rotary knob This mark will point to NAT or LP that indicates the type of gas the valve is set on 2 To...

Page 6: ...onic control valve is eqiuped with a HI LO solenoid HI LO DC motor drive or HI LO Step Motor locate the wiring connections on the HI LO device Note Figure 8 Figure 7 Figure 8 Wiring The AF 4000 MOD Mo...

Page 7: ...6 volt transformer to the 2 1 4 male terminals marked POWER on the module Note location on Figure 11 Optional If an AF 4000 BP battery pack is used follow the Wiring The AF 4000 BP Battery Pack secti...

Page 8: ...DC adaptor This adaptor is connected to the AF 4000 MOD by connecting the 2 1 4 female terminals from the adaptor to the 2 1 4 male terminals located on the AF 4000 MOD marked power Using the 6 0 volt...

Page 9: ...dden gas leaks can cause flashbacks in the appliance 2 Check for gas leaks with rich soap and water solution any time work is done on a gas system Gas Leak Test 1 Paint the pipe connectors upstream of...

Page 10: ...assembly and cleaning can cause unreliable operation Regular preventive maintenance is important in applications that place a heavy load on the system such as those used in commerical cooking agricul...

Page 11: ...F 4000 MOD module 3 Check the power sorce 1 the 6 volt power adaptor or the AF 4000 BP battery pack connections and condition of batteries 4 Optional check the position of the CONTINUOUS PILOT switch...

Reviews: