American Dynamics MegaPower 3200 User Manual Download Page 5

MEGAPOWER 3200 EXTENDED DOME/PTZ CAMERA PROTOCOL 

8200-0421-23, REV. A 

USER GUIDE 

3 of 25

 

Figure 3. Populated Protocol Handler Form 

 

5.  When you have added all the XML protocol 

configuration files that you want, click 

Close 

Protocol Handler Form

. The Direct 

Dome/PTZ Connections screen reappears. 

Note:

 

To delete a listed file,

 

highlight the 

appropriate file, and click 

Delete Selected 

Protocol Handlers

. This action only removes 

the file from the list and the MPCPU 
configuration data file; it does not delete the 
XML file from the PC disk drive. 

Configuring Camera Protocol 
Handlers 

To configure the camera control handlers, do the 
following: 

1.  In the RS-422/485 1 section and/or 

RS-422/485 2 section, choose 

RS-422/RS-485

 

or 

RS-232

, depending on the camera physical 

connections type, from the dropdown menu in 
the Dome/PTZ Control field. 

Note:

 

The 1 and 2 at the end of a section 

name indicates port 1 and port 2 respectively. 

2.  In the RS-422/485 1 (and 2) sections, click the 

Protocol Handlers field, and a dropdown menu 
appears. 

Figure 4. RS-422/485 dropdown menu choices 

 

3.  Highlight the appropriate protocol handler for 

the cameras that you want to use. Another 
dropdown menu appears that allows you to 
choose the data rate. 

Figure 5. Protocol handler baud rate dropdown 

 

4.  Click on the appropriate baud rate, and the 

baud rate changes in the Protocol Handlers 
field. The baud rates available for a protocol 
handler are displayed for selection when the 
mouse cursor is positioned over the Protocol 
Handler field. 

Note:

 

If the same protocol handler file is used 

for both sections 1 and 2, they must be set to 
the same data rate.  A second data rate can be 
obtained by copying, renaming, and installing 
the file. 

5.  Choose the appropriate values for the other 

fields in each section: 

 

Starting Video Input No. 

 

Starting Dome/PTZ Address 

 

No. of Dome/PTZ Devices 

6.  Save your new configuration before continuing. 

Installing and Operating 

For specific installation and operation information 
on extended dome/PTZ protocols for the MP3200 
system, refer to the respective camera protocol 
appendix. 

The extended dome/PTZ camera protocols use 
only one-way (simplex) communications to the 
dome/PTZ camera; therefore data return lines are 
not required. However, only American Dynamics 
dome/PTZ camera devices connected with 
American Dynamics RS-422/-485 control with 
return data or SensorNet can provide the following 
features: 

 

Camera Status screen information in these 
columns: 

 

Dome/PTZ On-Line 

 

Mnemonic 

Summary of Contents for MegaPower 3200

Page 1: ...8200 0421 23 A MegaPower 3200 Extended Dome PTZ Camera Protocol User Guide...

Page 2: ......

Page 3: ...this Guide This user guide explains the installation configuration and operation of the extended camera communications protocols used in the MegaPower 3200 video matrix closed circuit television CCTV...

Page 4: ...l Handler XML File into Configuration 3 In the file handler screen navigate to the folder containing the XML protocol configuration files you downloaded and then highlight all the files that you want...

Page 5: ...ant to use Another dropdown menu appears that allows you to choose the data rate Figure 5 Protocol handler baud rate dropdown 4 Click on the appropriate baud rate and the baud rate changes in the Prot...

Page 6: ...meter values have been improperly set or omitted this error condition will not be detected until an attempt is made to control a camera and it does not work correctly Overview of Camera Control Defini...

Page 7: ...each byte of data This value must be 1 or 2 It must match what your camera is configured to expect Parity specifies if and what type of parity bit to send with each byte If set to none no parity is se...

Page 8: ...for any particular purpose NOTICE The information in this manual was current when published The manufacturer reserves the right to revise and improve its products All specifications are therefore sub...

Page 9: ...exadecimal bytes that is each data byte is in hexadecimal format For example Hex 06 and 12 represents decimal numbers 06 and 22 respectively Table 3 outlines the BBV Star Card format Table 3 BBV Star...

Page 10: ...xBF check Command Name PanRightStart Template xB0 camera x00 x02 x20 x00 xBF check Command Name TiltDownStart Template xB0 camera x00 x10 x00 x20 xBF check Command Name TiltUpStart Template xB0 camer...

Page 11: ...MEGAPOWER 3200 EXTENDED DOME PTZ CAMERA PROTOCOL 8200 0421 23 REV A USER GUIDE 9 of 25 BBV Star Card Wiring Diagrams RS 232 Port Connections RS 422 Port Connections MPCPU MPCPU...

Page 12: ...MEGAPOWER 3200 EXTENDED DOME PTZ CAMERA PROTOCOL 8200 0421 23 REV A USER GUIDE 10 of 25 RS 422 Master Port Connections MPCPU...

Page 13: ...Autodome protocol Table 6 Bosch Autodome keyboard dome commands Keyboard Dome Menu Access Commands AD2089 No Command ADCC1100 No Command ADCC300 No Command ADTTE No Command Format The Bosch Autodome c...

Page 14: ...Iris C Foc F 3 0 Focus Near Zoom In Zoom 0ut Tilt Up Tilt Down Pan Left Pan Right 6 Lens Control 1 0 0 0 0 0 0 0 0 2 0 0 Iris 0pen Iris Close Focus Far Focus Near Zoom In Zoom 0ut 7 Aux Prepos 1 0 Num...

Page 15: ...01 x00 check Rate 20 Command Name FocusNearStart Template x86 camera x04 x00 x40 check Rate 20 Command Name IrisOpenStart Template x87 camera x08 x00 x04 x00 check Rate 20 Command Name IrisCloseStart...

Page 16: ...MEGAPOWER 3200 EXTENDED DOME PTZ CAMERA PROTOCOL 8200 0421 23 REV A USER GUIDE 14 of 25 Bosch AutoDome Wiring Diagram LTC 0945 15C MPCPU...

Page 17: ...de and typing 95 Preset Format The Pelco D command string uses 7 hexadecimal bytes that is each data byte is in hexadecimal format For example Hex 06 and 12 represents decimal numbers 06 and 22 respec...

Page 18: ...g is provided which gets translated before being sent to the camera In this handler the command begins with the camera address which is inserted using the camera parameter Each command ends with a che...

Page 19: ...check Command Name TiltDownStop Template xFF camera x00 x00 x00 x00 check Count 2 Command Name TiltUpStart Template xFF camera x00 x08 x00 x30 check Command Name TiltUpStop Template xFF camera x00 x0...

Page 20: ...tra II Model VDD5BC Ver 3 31 with housing BB5A PG E Spectra III Model DD53CDW Spectra III Model DD53TC16 Spectra IV SE Model DD4CBW35 Spectra IV SE Model DD4C22 Ver V1 072 with Back Box BB4 F MPCPU No...

Page 21: ...by going into Keyboard programming mode and typing 95 Preset Format The Pelco P command string uses 8 hexadecimal bytes that is each data byte is in hexadecimal format For example Hex 06 and 12 repres...

Page 22: ...definition the template string is provided which gets translated before being sent to the camera In this handler the command begins with the camera address which is inserted using the camera parameter...

Page 23: ...xA0 camera x00 x00 x00 x00 xAF check Count 2 Command Name TiltUpStart Template xA0 camera x00 x08 x00 x2F xAF check Command Name TiltUpStop Template xA0 camera x00 x00 x00 x00 xAF check Count 2 Comma...

Page 24: ...tra II Model VDD5BC Ver 3 31 with housing BB5A PG E Spectra III Model DD53CDW Spectra III Model DD53TC16 Spectra IV SE Model DD4CBW35 Spectra IV SE Model DD4C22 Ver V1 072 with Back Box BB4 F Note The...

Page 25: ...ENDED DOME PTZ CAMERA PROTOCOL 8200 0421 23 REV A USER GUIDE 23 of 25 Appendix E Block Diagrams Dual MPCPU system with RS 422 RS 485 direct connection dome PTZ devices using RS 422 RS 485 Distribution...

Page 26: ...PTZ CAMERA PROTOCOL 8200 0421 23 REV A USER GUIDE 24 of 25 Single MPCPU system with one dome PTZ on each of the two connections Single MPCPU using RS 232 mode to connect to the first RS 422 RS 485 Di...

Page 27: ...other encoding You can also include the characters shown in Table 19 using the XML syntax such as amp but non printing characters will be difficult to read in the debug window Table 19 Special XML cha...

Page 28: ......

Page 29: ...s Reserved Product specifications subject to change without notice Certain product names mentioned herein may be trade names and or registered trademarks of Tyco or other companies 8200 0421 23 A Plea...

Reviews: