31
4. Steam Damper Air System Connections
The MLS-55 is manufactured with a pneumatic (piston) damper system which requires an external supply
of compressed air. The air connection is made to the steam damper solenoid valve, which is located at the
rear inner top area of the dryer just in front of the electric service relay box.
a. Air Requirements
b. Air Connection
Air connection to system -- 1/8-inch N.P.T.
c. No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 PSI (5.52
bars)
must be
provided. It is suggested that a regulator/filter gauge arrangement be added to the
compressed air line just before the dryer connection. This is necessary to insure that correct and clean
air pressure is achieved.
C
OM P RESSED
A
IR
S
UPP LY
A
IR
P
RESSURE
Normal
80 PSI
5.52 bars
Minimum Supply
70 PSI
4.83 bars
Maximum Supply
90 PSI
6.21 bars
Shaded areas are stated in metric equivalents
Summary of Contents for Gas/Electric/Steam ML-55HS
Page 21: ...17 ...
Page 56: ...ADC 113000 9 11 23 05 0 ...