24
b. Electrically Heated Models Only
The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, L3, and
sometimes neutral) and ground. Single-phase (1ø) power for the control circuit and for any single-phase
(1ø) motors (if present) is done internally to the dryer by the factory at the oven contactor. No single-
phase (1ø) input connection is required on a 3-phase (3ø) dryer.
CAUTION
: The dryer
must be
grounded. A ground lug has been provided for this purpose.
Input connection wiring
must be
sized properly to handle the dryer's current draw. This information is
printed on the dryer's data label.
IMPORTANT
: A separate circuit servicing each dryer
must be
provided.
The electrical input connections are made at the electric oven contactor located inside the assembly at
the rear center upper section of the dryer. The ground connection is made to a copper lug also provided
in this area. To gain access, remove oven rear service cover.
IMPORTANT
: A strain relief
must be
used where the input wiring enters the oven assembly.