65
SECTION XII
TROUBLESHOOTING
IMPORTANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY
AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY
COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO
ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR
TESTING OF ANY EQUIPMENT PER OSHA
(Occupational Safety and
Health Administration)
STANDARDS.
The information provided will help isolate the most probable components associated with the difficulty described.
The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault
where electrical components are concerned...not necessarily the suspect component itself. Electrical parts
should always be
checked for failure before being returned to the factory.
IMPORTANT:
When replacing blown fuses, the replacement
must be
of the exact rating as the fuse
being replaced. The information provided
should not be
misconstrued as a
handbook for use by an untrained person in making repairs.
WARNING: ALL
SERVICE AND TROUBLESHOOTING
SHOULD BE
PERFORMED BY A
QUALIFIED PROFESSIONAL OR SERVICE AGENCY.
WARNING:
WHILE MAKING REPAIRS, OBSERVE
ALL
SAFETY PRECAUTIONS
DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL.
A.
No Display...
1. “EMERGENCY STOP” (E-Stop) button pushed in.
2. Service panel fuses blown or tripped breaker.
3. Blown F2 (fuse 2) on microprocessor controller (computer) input/output (I/O) board.
4. Blown CB7 (circuit breaker) on right hand control panel.
5. Failed display board.
6. Failed communication cable.
7. Failed microprocessor controller (computer) I/O board.
8. Optional sprinkler circuit emergency relay is not engaged...
a. Service panel fuse blown or tripped breaker.
b. Sprinkler circuit hi-limit has tripped.
Summary of Contents for AD-310
Page 11: ...7 310 NON TILT GAS MODEL B DIMENSIONS AND COMPONENT LOCATION ...
Page 12: ...8 310 NON TILT STEAM MODEL ...
Page 14: ...10 1 Reassembly Instructions For Gas Dryer Shipped In Two 2 Pieces ...
Page 16: ...12 2 Reassembly Instructions For Steam Dryer Shipped In Two 2 Pieces ...
Page 22: ...18 ...
Page 23: ...19 ...
Page 24: ...20 ...
Page 64: ...60 B I O BOARD INPUT AND OUTPUT L E D INDICATORS ...
Page 80: ...76 ...