Power Supply:

 The American DJ

®

 Quad Scan LED contains a auto-

matic voltage switch, which will auto sense the voltage when it is 

plugged into the power source. With this switch there is no need to 

worry about the correct power voltage, this unit can be plugged in 

anywhere.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 

communication between intelligent fixtures and controllers. A DMX 

controller sends DMX data instructions from the controller to the fix-

ture. DMX data is sent as serial data that travels from fixture to fixture 

via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 

fixtures (most controllers only have a DATA “OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 

single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 

compliant.  To ensure proper DMX data transmission, when using 

several DMX fixtures try to use the shortest cable path possible. The 

order in which fixtures are connected in a DMX line does not influence 

the DMX addressing. For example; a fixture assigned a DMX address 

of 1 may be placed anywhere in a DMX line, at the beginning, at the 

end, or anywhere in the middle. Therefore, the first fixture controlled 

by the controller could be the last fixture in the chain. When a fixture 

is assigned a DMX address of 1, the DMX controller knows to send 

DATA assigned to address 1 to that unit, no matter where it is located 

in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 

Operation): 

The Quad Scan LED can be controlled via DMX-512 pro-

tocol.  The  Quad  Scan  LED  can  be  a  1,  5,  or  28 

channel DMX unit. The DMX address is set elec-

tronically using the controls on the bottom panel of 

the unit. Your unit and your DMX controller require 

a approved DMX-512 110 Ohm Data cable for data 

input and data output (Figure 1). We recommend 

Accu-Cable DMX cables. If you are making your 

own cables, be sure to use standard 110-120 Ohm 

shielded cable (This cable may be purchased at 

almost all professional sound and lighting stores). Your cables should 

 Quad Scan LED   

                                           Set Up

Figure 1

 Quad Scan LED    

                    Hanging Precautions

Fixture installation must always be secured with a secondary 

safety attachment, such as an appropriate safety cable.
Regardless of the rigging option you choose for your Quad 

Scan LED always be sure to secure your fixture with a safety 

cable (not included). Attach a safety cable to the provided 

safety bolt.  
Caution: For added protection mount the fixtures in areas out-

side of walking paths, seating areas, or areas were the fixture 

might be reached by unauthorized personal. 
Before mounting the fixture to any surface, make sure that the 

installation area can hold a minimum point load of 10 times the 

device’s weight.
To avoid injury, never stand directly below the device when 

mounting, removing, or servicing the fixture.
Always use and install a safety cable ( not included) as a safety 

measure to prevent accidental damage and/or injury in the 

event the clamp fails. 
Be sure to complete all rigging and installation procedures 

before connecting the main power cord to the appropriate wall 

outlet.

Summary of Contents for Quad Scan LED

Page 1: ...ED is a DMX intelligent RGB Tri LED scanner The Quad Scan LED can operate as a stand alone fixture or in a Master Slave configuration The Quad Scan LED has three operating modes sound active mode show...

Page 2: ...en spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Quad Scan LED Safety Prec...

Page 3: ...DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX and Master Slave Operation The Quad Scan L...

Page 4: ...12 IN 3 PIN XLR SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT POWER INPUT OUTPUT DMX512 DMX DMX COMMON 1 2 3 Termination reduce...

Page 5: ...ed DMX mode and press ENTER to confim and exit SLND This will let you set unit as a master or slave in a master slave configuration 1 Press the MENU button until SLND is displayed press ENTER Either M...

Page 6: ...ogram 1 Press the MENU button until TEST is displayed press Quad Scan LED System Menu between 0 16 Programs 0 16 are factory programs while Show 0 is random mode Press the UP or DOWN buttons to find y...

Page 7: ...pages 16 21 for detailed description of the DMX values and traits 2 To control your fixture in DMX mode follow the set up procedures on pages 6 8 as well as the set up specifications that are includ...

Page 8: ...MX data cables daisy chain your units togeth er via the XLR connector on the rear of the units Remember the Male XLR connector is the input and the Female XLR connector is the output The first unit in...

Page 9: ...1 SLOW OPEN FAST CLOSE 182 189 OPEN 190 231 FAST OPEN SLOW CLOSE 232 239 OPEN 240 247 SOUND ACTIVE STROBING 248 255 OPEN Quad Scan LED 5 Channel Mode DMX Traits Channel Value Function 5 COLOR CHASE 0...

Page 10: ...EN MIRROR 2 0 255 0 100 12 BLUE MIRROR 2 0 255 0 100 13 MASTER DIMMER MIRROR 2 0 255 0 100 14 STROBING MIRROR 2 0 8 OPEN 9 131 STROBING SLOW FAST 132 139 OPEN Quad Scan LED 28 Channel Mode DMX Traits...

Page 11: ...j com Quad Scan LED Instruction Manual Page 22 American DJ www americandj com Quad Scan LED Instruction Manual Page 21 Quad Scan LED 28 Channel Mode DMX Traits Channel Value Function 26 BLUE MIRROR 3...

Page 12: ...DJ Inc if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or per...

Reviews: