WALL PANEL/LINER INSTALLATION (continued)
TIME REQUIRED
3-4 HR
10
1T
C - Installing Panels
8. Sand the backside surface of the wall panels with 60 grit sandpaper. This will increase the bond
to the silicone. Remove all dust and dirt with a clean dry cloth.
9. Start with panel 2B, apply a generous amount of silicone to the cement board and to the back
side of the wall panel. Refer to “Silicone Recommendations” on previous page for applying
silicone. Also refer to the manufacturer’s recommendations for application and drying time.
10. Press the wall firmly into position. Be sure to use spacers between the bottom panel and the
shower pan to ensure panel is level.
(diagram 12)
11. Install the remaining panels in the following order: 1B, 1L, 2B, 2L, 1T, 1LT, 2T & 2LT.
Match the space between the panels with the rest of the grout lines on the panel.
Use spacers if necessary to make the walls square and straight.
diagram 12
THRESHOLD TRIM
TIME REQUIRED
1/2 - 1 HR
11
8
The threshold trim pieces complete the look of your new shower system. If you purchased a Basic
Package which does not come with glass, your threshold pieces will be solid, without a channel. If
you purchased a Supreme Package which comes with glass, the threshold pieces will have a channel
for the glass panels. No matter what package you ordered there are 2 special cap trim pieces and 2
special notched bottom left and right pieces.
1. Locate all the trim pieces and align them on the floor.
(diagram 13)
2. Apply silicone, using a zig-zag pattern, to the cement board along the panel’s edge, approximately
4 inches out: to the far outside of the shower pan.
(diagram 14)
Do not install the small cap trim pieces if your package includes glass. These trim pieces are to be
installed after the glass and door have been installed. If you did not purchase a package
with glass, you can install the cap trim pieces now.
3. Starting with the special bottom threshold piece, place the threshold into position making sure to
align the threshold with the vertical plumb line previously drawn on the cement
board. Apply pressure to the trim piece to bond it to the cement board. The trim piece should be
flush with the inside of the shower pan threshold.
(diagram 15)
Make sure to align the glass
channels in the thresholds with the glass channels in the shower pan. (if glass unit)
4. Place the remaining trim pieces into position. Make sure to use a level and the plumb line
previously drawn on the cement board to align the trim pieces vertically.
Wall thresholds should be flush on the inside and
outside of the pan
See manufacturer’s recommendations for drying time
cap trim pieces
TLC
TRC
TLT
TRT
TLB
TRB
diagram 13
special notched bottom pieces
diagram 14
diagram 15
1B
1L
2T
2L
2B
B races may be required to keep walls flush
cement
board
2LT
1LT