Basic Move Types (continued)
Absolute Move
Absolute Moves move from the Current Position (A)
to a given position (B). (The SMD34K calculates the
direction and number of steps needed to move to the
given position and moves that number of steps.) A
trapezoidal profile is shown to the right, but Absolute
Moves can also generate triangular profiles. The com-
mand’s Target Position can be in the range of
±8,388,607 counts. The move will be clockwise if the
Target Position is greater than the Current Position and
counter-clockwise if the Target Position is less than
the Current Position.
1) The
Home Position
of the machine must be set before running an Absolute Move. See the
, which starts on page 51, for information on hom-
ing the machine.
2) The Motor Position must be valid before you can use an Absolute Move. (The Position
Invalid status bit cannot be on.) The Motor Position becomes valid when you preset the
position or home the machine.
3) Absolute Moves allow you to move your machine without having to calculate relative posi-
tions. If you are controlling a rotary table, you can drive the table to any angle without hav-
ing to calculate the distance to travel. For example an Absolute Move to 180° will move the
table to the correct position regardless of where the move starts from.
Controlled Stops
The move completes without error.
You toggle the Hold_Move control bit in the Network Output Data. Note that your holding position will
most likely not be the final position you commanded. You can resume a held Absolute Move by using
the Resume_Move bit or the move can be aborted by starting another move. The use of the Hold_Move
and Resume_Move bits is explained in the
Immediate Stops
The Immediate Stop bit makes a 0
1 transition in the Network Input Data.
An inactive-to-active transition on an input configured as an E-Stop Input.
A CW or CWW Limit Switch is reached. If the limit that is reached is the same as the direction of
travel, for example, hitting the CW limit while running a CW move, a
Reset Errors
command must be
issued before moves are allowed in that direction again. If the limit that is reached is opposite the direc-
tion of travel, a
Reset Errors
command does not have to be issued.
Figure R2.7 Absolute Move
SP
E
E
D
POSITION
A
B
Summary of Contents for SMD34K
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S280 ...
Page 6: ...TABLE OF CONTENTS SMD34K User Manual ADVANCED MICRO CONTROLS INC 6 Notes ...
Page 50: ...CALCULATING MOVE PROFILES SMD34K User Manual ADVANCED MICRO CONTROLS INC 50 Notes ...
Page 62: ...CONFIGURATION DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 62 Notes ...
Page 80: ...COMMAND DATA FORMAT SMD34K User Manual ADVANCED MICRO CONTROLS INC 80 Notes ...
Page 100: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC ...