U10C034 Telephony Version v1.4 June 2008
74
5.4 Battery Trap
The following traps will be sent to SNMP management if battery status is changed. MSO operators
can understand current battery and modem situation when trap is received..
PS: NMAccess must be configured for SNMP trap sent.
Alarm Name
OID
Description
upsAlarmGeneralFault
1.3.6.1.2.1.33.1.6.3.18.0
A general fault in the UPS has been
detected.
upsAlarmOnBattery
1.3.6.1.2.1.33.1.6.3.2.0
The UPS is drawing power from the
batteries.
upsAlarmLowBattery
1.3.6.1.2.1.33.1.6.3.3.0
The remaining battery run-time is less than
or equal to upsConfigLowBattTime.
upsAlarmDepletedBattery
1.3.6.1.2.1.33.1.6.3.4.0
The UPS will be unable to sustain the
present load when and if the utility power
is lost.
upsAlarmBatteryBad
1.3.6.1.2.1.33.1.6.3.1.0
One or more batteries have been
determined to require replacement.
upsAlarmShutdownImminent
1.3.6.1.2.1.33.1.6.3.23.0
The UPS will turn off power to the load in
less than 5 seconds; this may be either a
timed shutdown or a low battery
shutdown.
upsAlarmShutdownPending
1.3.6.1.2.1.33.1.6.3.22.0
A upsShutdownAfterDelay countdown is
underway.
upsAlarmUpsOutputOff
1.3.6.1.2.1.33.1.6.3.14.0
The output of the UPS is in the off state.
upsAlarmOutputOffAsRequested
1.3.6.1.2.1.33.1.6.3.11.0
The UPS has shutdown as requested, i.e.,
the output is off.
upsAlarmAwaitingPower
1.3.6.1.2.1.33.1.6.3.21.0
The UPS output is off and the UPS is
awaiting the return of input power.
bcmAlarmTempBadChargeSuspended 1.3.6.1.4.1.4413.2.2.2.1.10.4.2.0
The temperature of the device has exceeded
operational limits for safe battery charging,
and battery charging has been suspended.
bcmAlarmTempBadPowerReduced
1.3.6.1.4.1.4413.2.2.2.1.10.4.3.0
The temperature of the device has exceeded
operational limits, and the device has been
placed in low power mode in an to attempt
to reduce heat production.
Summary of Contents for U10C034
Page 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Page 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Page 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Page 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Page 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Page 55: ...55 3 5 Event Log ...
Page 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Page 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Page 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Page 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Page 61: ...61 3 11 QoS Display service flow information ...
Page 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Page 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...