U10C034 Telephony Version v1.4 June 2008
32
will be held in the jitter buffer for at least this duration (on average).
When a packet is received late it may be held for less than this time.
emtaSignalingVoiceJitterMaxValue
(1.3.6.1.4.1.4413.2.2.2.1.6.4.6.0 Unsigned32)
If the voice jitter buffer value is changed through SNMP, then those changes
take affect starting with the next phone call (in process calls are not
affected). This MIB sets the maximum hold time for the voice jitter buffer
in milliseconds. The maximum size of the jitter buffer is only relevant
for an adaptive jitter buffer. The target hold time cannot take on a value
greater
than
the
maximum
either
through
a
MIB
setting
or
through
adaptation.
On average, packets will not be held longer than this time. However, if
a packet is received quite early it may be held longer than the max hold
time. The default value is 0 which is interpreted as the maximum jitter
buffer size for the product.
emtaSignalingDataJitterNomValue
(1.3.6.1.4.1.4413.2.2.2.1.6.4.7.0 Unsigned32)
If the jitter buffer value is changed through SNMP, then those changes
take affect starting with the next phone call (in process calls are not
affected). This object controls the hold time for a fixed VBD jitter buffer.
The jitter buffer always fixes itself when VBD is detected and never adapts
below this level, so this value serves as a minimum too. The default value
is 60 msec..
emtaSignalingDataJitterMaxValue
(1.3.6.1.4.1.4413.2.2.2.1.6.4.19.0 Unsigned32)
If the voice buffer value is changed through SNMP, then those changes
take affect starting with the next phone call (in process calls are not
affected). This MIB sets the maximum hold time for the fixed VBD jitter
buffer and is only relevant when emtaSignalingVoiceJitterBufferType is
set to 'jitterbufferTypeFixed(1)'. The default value is 0 which is
interpreted as the maximum jitter buffer size for the product.
emtaStatsAvgJitterMeasurement
(1.3.6.1.4.1.4413.2.2.2.1.6.5.8.0 Unsigned32)
This objects contains the average jitter measurements for the last 24
hours.
emtaStatsMaxJitterMeasurement
(1.3.6.1.4.1.4413.2.2.2.1.6.5.9.0 Unsigned32)
This objects contains the maximum jitter measurements for the last 24
hours.
Summary of Contents for U10C034
Page 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Page 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Page 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Page 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Page 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Page 55: ...55 3 5 Event Log ...
Page 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Page 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Page 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Page 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Page 61: ...61 3 11 QoS Display service flow information ...
Page 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Page 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...