U10C034 MSO User’s Manual v1.4 June 2008
37
emtaSignalingEndptConnectionCleanupTimeo
ut
60
Read
emtaSignalingEmtaResetCleanupTimeout
0
Read
emtaSignalingEndptConnectionCleanupTimeout
(1.3.6.1.4.1.4413.2.2.2.1.6.4.12.0 Unsigned32)
This object causes the EMTA to tear down and clean up connections and
the associated service flows on any endpoint that detects a transition
from off-hook to on-hook, remains onhook for a period longer than the
value set in this MB object, and has connections that were active prior
to the endpoint going onhook. If the MIB object is set to 0 then this
function is disabled. If the MIB is set from 1 to 64000 seconds then the
feature is enabled and this value is used for the timeout. This object
should only be changed by the configuration file.
emtaSignalingEmtaResetCleanupTimeout
(1.3.6.1.4.1.4413.2.2.2.1.6.4.13.0 Unsigned32)
This object causes the entire EMTA to reset if voice connections have
been active and both voice lines have been on-hook for a period greater
than
the
value
defined
via
this
MIB
object.
This
will
guarantee
that
orphaned
connections and/or service flows are properly cleaned up and freed when
the CMTS and CMS fail to perform the correct clean up operations. It will
also ensure that the EMTA state machine, DSP voice channels, NCS connection
handling, etc. are also restored to a default state. This protects against
any unknown case that could possibly cause stuck service flows and/or
connections. If the MIB object is set to 0 then this function is disabled.
If the MIB is set from 1 to 64000 minutes then the feature is enabled
and this value is used for the timeout. This object should only be changed
by the configuration file.
2.2.8 EndPoint Provisioning
brcm-emta-mgmt.mib
MIB
Default Value
Access
emtaRingWithDCOffset
false
read-write
emtaSignalingEndptCtrlAnalogLoopback
false
read-write
emtaSignalingEndptCtrlLineReset
false
read-write
emtaSignalingEndptCtrlBoostedLoopCurrent
false
read-write
emtaSignalingEndptCtrlTxGain
0
read-write
emtaSignalingEndptCtrlRxGain
0
read-write
emtaSignalingEndptCtrlDialToneMsecTO
0
read-write
Summary of Contents for U10C034
Page 1: ...U10C034 Telephony MSO User s Manual Version 1 4 Date Aug 2008 ...
Page 2: ...U10C034 Telephony Version v1 4 June 2008 ii ...
Page 4: ...U10C034 Telephony Version v1 4 June 2008 iv ...
Page 17: ...U10C034 MSO User s Manual v1 4 June 2008 17 ...
Page 54: ...U10C034 Telephony Version v1 4 June 2008 54 3 4 CM Hardware ...
Page 55: ...55 3 5 Event Log ...
Page 56: ...U10C034 Telephony Version v1 4 June 2008 56 3 6 CM State ...
Page 58: ...U10C034 Telephony Version v1 4 June 2008 58 3 8 Product Display status interface information ...
Page 59: ...59 3 9 DHCP Display CM and MTA DHCP information ...
Page 60: ...U10C034 Telephony Version v1 4 June 2008 60 3 10 MTA Display some detail MTA parameters ...
Page 61: ...61 3 11 QoS Display service flow information ...
Page 63: ...63 3 13 Event Log Display CM and MTA event logs ...
Page 90: ...U10C034 Telephony Version v1 4 June 2008 90 U10C034 Telephony MSO User s Manual ...