Cleaning, maintenance and repairs
Air reservoir
Drain the air reservoir every day.
Draining the air reservoir
Fig. 122/...
(1) Air reservoir
(2) Tensioning belts
(3) Drainage valve
(4) Test connection for pressure gauge
1. Pull the drain valve (Fig. 122/3) in a side-
ways direction using the ring until no more
water escapes from the air reservoir (Fig.
122/1).
→
Water flows out of the drain valve (Fig.
122/3).
2. Unscrew the drain valve (Fig. 122/3) from
the air reservoir and clean the reservoir if
there are signs of dirt.
Fig. 122
Line filter
•
Change damaged filter inserts.
1. Press together the locking piece (Fig.
123/1) on the two lugs.
2. Remove the locking piece with O-ring, pres-
sure spring and filter insert.
3. Clean (rinse out) the filter insert with petrol
or thinner and blow dry with compressed
air.
4. Press together the locking piece (Fig.
123/1) on the two lugs.
5. Insert the locking piece with O-ring, pres-
sure spring and filter insert.
Fig. 123
When inserting the locking piece,
make sure that the O-ring is not twist-
ed in the guide slot.
ZG-B
BAG0003.18 01.19
163