Commissioning
6.1.2.2
Compare the permissible D
C
value with actual D
C
value
WARNING
Danger from breaking the coupling devices between the tractor
and the implement when the tractor is not used for its intended
purpose!
1. Calculate the actual D
C
value of your combination, comprising
tractor and implement.
2. Compare the actual D
C
value with the following permissible D
C
values:
•
Coupling device of the implement
•
Drawbar of the implement
•
Coupling device of the tractor
The actual D
C
value calculated for the combination must be less than
or equal (
≤
) to the D
C
values specified.
The permissible D
C
values of the implement can
be found on the rating plate of the coupling de-
vice (1) and the drawbar (2).
The permissible D
C
value of the tractor coupling
device can be found directly on the coupling
device / in the operating manual of your tractor.
actually calculated
D
C
value for the combination
specified D
C
value
kN
≤
Coupling device on the tractor
kN
≤
Coupling device of the implement
kN
≤
Drawbar of the implement
kN
Ceus-2TX BAG0183.2 01.19
75