background image

ERS1*1E     ERS1*2E     EWC100

Page 1

97574C (Rev. K - 05/16)

B

A

D

B

A

8 C

S

4

1

2R

E

F

G

C

B

A

7"

179mm

6 1/4"

160mm

2 3/8"

61mm

1 1/8"

28mm

2 3/8"

61mm

10"

253mm

17 1/8"

434mm

2"

51mm

14"

354mm

E

D

C

A

B

3 1/2"

89mm

LEGEND

A = 1/4" O.D. TUBE WATER OUTLET

       TUBO DE 1/4" DE DIÁMETRO EXTERNO 

       DE SALIDA DE AGUA

       TUBE DE SORTIE D'EAU DE D.E. 1/4"

B = 1/4" O.D. TUBE WATER INLET

       TUBO DE 1/4" DE DIÁMETRO EXTERNO  

       DE ENTRADA DE AGUA

       TUBE DE ENTRÉE D'EAU DE D.E. 1/4"

C = TEMPERATURE ADJUSTMENT

       AJUSTE DE TEMPERATURA

       RÉGLAGE DE TEMPÉRATURE

D = ELECTRICAL

       ELÉCTRICO

       ÉLECTRICITÉ

E = 1/4" O.D. TUBE TANK DRAIN

       TUBE DE 1/4" DE DIÁMETRO EXTERNO  

       DESAGÜE DEL TANQUE

       TUBE DE D.E. 1/4" DE VIDANGE DU

       RÉSERVOIR

INSTALLATION, CARE & USE MANUAL

Refrigeration Package

A) WHITE

BLANCO

BLANC

B) BLACK

NEGRO

NOIR

C) GROUND

TIERRA

MISE À LA TERRE

D) FAN

ABANICO

VENTILATEUR

E) COLD CONTROL

CONTROL DE FRÍO

THERMOSTAT

F) INTERNAL OVERLOAD PROTECTOR

PROTECTOR INTERNO DEL SOBRECARGADOR

SYSTEME DE PROTECTION DE SURCHAGE INTERNE

G) PTC STARTER

INICIADOR CPT (CONTROL POSITIVO DE TEMPERATURA)

DEMARREUR CTP

Fig. 1

115V Wiring Diagram

Fig. 2

USES HFC-134A REFRIGERANT     USA REFRIGERANTE HFC-134A     UTILISE DU FLUIDE FRIGORIGÈNE HFC-134A

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for ERS1 1E Series

Page 1: ...CTRICO ÉLECTRICITÉ E 1 4 O D TUBE TANK DRAIN TUBE DE 1 4 DE DIÁMETRO EXTERNO DESAGÜE DEL TANQUE TUBE DE D E 1 4 DE VIDANGE DU RÉSERVOIR INSTALLATION CARE USE MANUAL Refrigeration Package A WHITE BLANCO BLANC B BLACK NEGRO NOIR C GROUND TIERRA MISE À LA TERRE D FAN ABANICO VENTILATEUR E COLD CONTROL CONTROL DE FRÍO THERMOSTAT F INTERNAL OVERLOAD PROTECTOR PROTECTOR INTERNO DEL SOBRECARGADOR SYSTEME...

Page 2: ...2 Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected Steady stream assures all air is removed 3 Rotate fan to insure proper clearance and free fan action 4 Connect to electrical power TROUBLE SHOOTING MAINTENANCE Temperature Control Factory set at 50 F 5 under normal conditions For colder water adjust screw on item no 8 in clockwise direction See Fig...

Page 3: ...ION 1 L appareil a été conçu pour être installé sous un évier de cuisine conventionnel dans un placard d une largeur minimum de 9 14m 36 pieds dimensions intérieures Le placard doit contenir deux ouvertures d aération d un minimum de 10 16cm carrés 40 pouces chacune représentant un minimum de 75 de l espace ouvert L une des ouvertures doit surplomber l espace gain de place L autre ouverture doit s...

Page 4: ...er Drier Cold Control Compr Service Pak EM20HBR Kit Fan Mtr Blade Nut Kit Compressor Mtg Hdwe Kit Condenser Drier Drier Drain Plug Kit Evaporator Assy Soporte del Motor Ventilador Panel Frontal Cubierta para Electricidad Lateral Derecho y Posterior Lateral Izquierdo y Superior Kit Eléctrico Sobrecarga Relé Cubierta Kit Intercambiador de Calor Secador Controlador de Frío Paquete de Serv del Compres...

Reviews: