600A AC/DC Clamp Meter, True RMS, NCV, Flashlight, 

6000 Count
Pinza Amperimétrica CA / CC de 600 A, True RMS, NCV, 

Linterna, 6000 Cuentas
Pince Ampèremétrique CA/CC 600 A, à Valeur Efficace Vraie, 

Détection de Tensions sans Contact (NCV), Lampe-Torche, 

Écran 6 000 Comptes
B07VX41MPR

Summary of Contents for B07VX41MPR

Page 1: ...NCV Flashlight 6000 Count Pinza Amperim trica CA CC de 600 A True RMS NCV Linterna 6000 Cuentas Pince Amp rem trique CA CC 600 A Valeur Efficace Vraie D tection de Tensions sans Contact NCV Lampe Torc...

Page 2: ...English 3 Espa ol 36 Fran ais 69...

Page 3: ...owing WARNING Risk of electric shock Improper use of this product can cause damage shock injury or death WARNING Risk of electric shock The safety features of this product may not protect the user if...

Page 4: ...Mode Maximum Input A A 600 A V V 1000 V Resistance Capacitance Frequency Diode Test Temperature 300 V Do not measure current on a CAT II circuitry whose voltage exceeds 1000 V Do not measure current...

Page 5: ...icult and misleading because of the uncertainty of connection to the recessed electrical contacts Do not use this product for checking socket outlets Use special equipment for checking socket outlets...

Page 6: ...nd new batteries or batteries of different types or brands Exhausted batteries should be immediately removed from product and properly disposed Keep batteries out of the reach of children Do not dispo...

Page 7: ...elated to personal injury This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information This symbol adjacent to a terminal indicates that under...

Page 8: ...00 A CAT II 1000V Product is designed to protect the user during measurements performed on circuits directly connected to the low voltage installation up to 1000 V CAT III 600V Product is designed to...

Page 9: ...his product may be used only under the conditions and for the purposes for which it was designed No liability will be accepted for damages resulting from improper use or non compliance with these inst...

Page 10: ...10 EN Product Description A B C E F G H L K J O I M D P Q S N R...

Page 11: ...ge Detector indicator M V CAP Hz TEMP input terminal D Clamp trigger N Flashlight E REL button O Battery compartment cover F Display P Thermocouple probe adapter with caps G RANGE button Q Thermocoupl...

Page 12: ...current voltage 11 Diode test 3 Direct current voltage 12 Continuity 4 Minus sign 13 APO Auto power off 5 Low battery 14 C F Temperature unit 6 AUTO Automatic range setting 15 Unit of measurement 7 IN...

Page 13: ...tch Position Function Measurement AC DC current up to 600 A AC DC current up to 60 A Temperature Resistance capacitance Continuity diode test DC voltage AC voltage Frequency duty cycle variable freque...

Page 14: ...n the low battery indicator 5 is show on the display Turn the lock of the battery compartment cover O by 180 in an anti clockwise direction Open the battery compartment Replace 3 x 1 5 V AAA batteries...

Page 15: ...utomatic power off is enabled the APO indicator 13 appears To deactivate automatic power off press and hold the MODE VFD button H while switching the product on The APO indicator 13 does not appear Sw...

Page 16: ...the measurement range manually not in every measurement mode Press the RANGE button G to activate the manual mode and to disable the automatic range setting The AUTO indicator 6 disappears By every pr...

Page 17: ...to zero the measured value 18 The indicator 1 appears Press the REL button E again to show the absolute measurement The indicator 1 disappears Clamp measurement NOTICE Disconnect the test leads S from...

Page 18: ...rent Hz Frequency Duty cycle Direct current When measuring DC current allow time for the product to zero before taking a reading If necessary press the REL button E to zero the display 18 The indicato...

Page 19: ...nt and the reading hold on the display F Press the PEAK INRUSH button L for 2 seconds to return to normal operation The INRUSH indicator 7 disappears CAUTION Risk of short circuit Use the test probe s...

Page 20: ...ak values Press the PEAK INRUSH button L to switch between the maximum MAX and minimum MIN measured value The appropriate MAX MIN indicator 8 appears Press the PEAK INRUSH button L for 2 seconds to re...

Page 21: ...CE Press the MODE VFD button H for 2 seconds to return to normal operation The VFD indicator 10 disappears DC voltage measurement Insert the black connector lead S into the negative COM black terminal...

Page 22: ...rcuit or device being tested is open or has a resistance that is above the range of the product The stabilized value on the display F is read as the actual reading Capacitance measurement Insert the b...

Page 23: ...citors follow the polarity of its leads to have a precise measurement Frequency duty cycle measurement Insert the black connector lead S into the negative COM black terminal I and the red connector le...

Page 24: ...FD button H to shift to measuring the duty cycle in percent Connect the test probes S across the circuit or component being measured The stabilized value on the display F is read as the actual reading...

Page 25: ...ack connector lead S into the negative COM black terminal I and the red connector lead S into the positive V red terminal M Set the function switch K to the position Press the MODE VFD button H to cha...

Page 26: ...or into the positive V red terminal M Connect the thermocouple probe Q to the thermocouple probe adapter P The polarity marking of the probe Q must correspond to the marking of the adapter P The probe...

Page 27: ...s test the voltage detector on a known live circuit to verify proper operation NOTICE Insulation type and thickness distance from the voltage source shielded wires and other factors may effect reliabl...

Page 28: ...rgy may randomly trip the sensor The voltage detector only senses the presence of voltage It does not indicate the actual voltage on the display F Cleaning and Maintenance NOTICE Switch the product of...

Page 29: ...a dry area Keep away from children and pets Specifications NOTICE f m from measurement AC true rms current Range Resolution Accuracy 60 A 10 mA 2 0 f m 8 digits 600 A 100 mA 2 5 f m 8 digits Overrang...

Page 30: ...ltage with VFD Range Resolution Accuracy 6 V 1 mV 1 2 f m 5 digits 60 V 10 mV 600 V 100 mV 1000 V 1 V 1 5 f m 5 digits Variable frequency drive measurement AC voltage range 100 V 600 V AC voltage band...

Page 31: ...10 mV 1 0 f m 3 digits 600 V 100 mV 1000 V 1 V 1 2 f m 3 digits Maximum input 1000 V Resistance Range Resolution Accuracy 600 0 1 1 f m 4 digits 6 k 1 1 5 f m 2 digits 60 k 10 600 k 100 6 M 1 k 2 0 f...

Page 32: ...F 0 001 F 99 99 F 0 01 F 999 9 F 0 1 F 9 999 mF 0 001 mF 99 99 mF 0 01 mF 5 f m 5 digits Input Protection 300 V or 300 V rms NOTICE 99 99 nF no specification Frequency AC current Range Resolution Accu...

Page 33: ...Diode Measurement Output Forward DCA is approx 1 mA open circuit voltage max 3 V Forward voltage drop of diode Input Protection 300 V or 300 V rms Temperature Range Resolution Accuracy 20 C to 1000 C...

Page 34: ...I 600 V Pollution degree 2 Clamp jaw opening approx 1 3 33 mm Display 6000 counts backlit LCD Measurement rate 3 readings per second nominal Temperature sensor Type K thermocouple Input impedance 10 M...

Page 35: ...f after approx 15 minutes Feedback and Help Love it Hate it Let us know with a customer review AmazonCommercial is committed to delivering customer driven products that live up to your high standards...

Page 36: ...amazon com AmazonCommercial V01 10 19 MADE IN CHINA HECHO EN CHINA FABRIQU EN CHINE...