BLOWER PERFORMANCE SPECIFICATIONS
31
Rev. 2
TWO STAGE - VARIABLE SPEED
Cooling Speed Chart
(“Y” on Two-Stage Integrated Furnace Control or “Y/Y2 on Interface Board)
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
540
A
Minus
720
A
Normal
600
A
Normal
800
A
Plus
660
A
Plus
880
B
Minus
720
B
Minus
990
B
Normal
800
B
Normal
1100
B
Plus
880
B
Plus
1210
C
Minus
990
C
Minus
1260
C
Normal
1100
C
Normal
1400
C
Plus
1210
C
Plus
1540
D
Minus
1260
D
Minus
1620
D
Normal
1400
D
Normal
1800
D
Plus
1540
D
Plus
1980
GUIV70DX40
GUIV90DX50
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
900
A
Minus
900
A
Normal
1000
A
Normal
1000
A
Plus
1100
A
Plus
1100
B
Minus
1080
B
Minus
1080
B
Normal
1200
B
Normal
1200
B
Plus
1320
B
Plus
1320
C
Minus
1440
C
Minus
1440
C
Normal
1600
C
Normal
1600
C
Plus
1760
C
Plus
1760
D
Minus
1800
D
Minus
1800
D
Normal
2000
D
Normal
2000
D
Plus
2000
D
Plus
2000
GUIV115X50
GUIV140DX50
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
351
A
Minus
468
A
Normal
390
A
Normal
520
A
Plus
429
A
Plus
572
B
Minus
468
B
Minus
644
B
Normal
520
B
Normal
715
B
Plus
572
B
Plus
787
C
Minus
644
C
Minus
819
C
Normal
715
C
Normal
910
C
Plus
787
C
Plus
1001
D
Minus
819
D
Minus
1053
D
Normal
910
D
Normal
1170
D
Plus
1001
D
Plus
1287
GUIV70DX40
GUIV90DX50
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
Cooling
Speed
Adjust
CFM @
.1 to .8 "WC
ESP
A
Minus
585
A
Minus
585
A
Normal
650
A
Normal
650
A
Plus
715
A
Plus
715
B
Minus
702
B
Minus
702
B
Normal
780
B
Normal
780
B
Plus
858
B
Plus
858
C
Minus
936
C
Minus
936
C
Normal
1040
C
Normal
1040
C
Plus
1144
C
Plus
1144
D
Minus
1170
D
Minus
1170
D
Normal
1300
D
Normal
1300
D
Plus
1300
D
Plus
1300
GUIV140DX50
GUIV115X50
Low Stage Cooling Speed Chart
(“Y1” on Interface Board)
1. Units are shipped without filter(s). CFM in chart is without filter(s).
2. All furnaces shipped with heating speed set at "B" and cooling speed set at "A". Installer should adjust blower speeds
as needed.
3. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE
RATING PLATE.
4. The chart is for information only. For satisfactory operation, external static pressure not to exceed value shown on
rating plate.
5. The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have
approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.