![Alvarion BreezeACCESS II CX System Manual Download Page 62](http://html1.mh-extra.com/html/alvarion/breezeaccess-ii-cx/breezeaccess-ii-cx_system-manual_2915114062.webp)
Chapter
3 - Commissioning
Basic Parameters in BreezeACCESS VL SU
(SW Version 2.0)
Ethernet Port Negotiation Mode
WARNING
In mixed bands Cell Extenders with a BreezeACCESS VL SU, the Ethernet Port of the
BreezeACCESS VL SU must be configured to operate in 10 Mbps, Half-Duplex mode.
Table 3-5: Basic Parameters in BreezeACCESS VL SU
Parameter
Default Value
Comment
IP Address
10.0.0.1
Subnet Mask
255.0.0.0
Default Gateway Address
0.0.0.0
DHCP Options
Disable
Access to DHCP
reless Only
From Wi
ESSID ESSID1
Sub Band Select
Applicable only if more
than one Sub Band is
available.
1
Frequency Subset Definition
The list of frequencies is
in accordance with the
Sub Band.
A (All)
Tx Power for Modulation Levels 1
to 5
Tx Power for Modulation Level 6
Tx Power for Modu
lation Level 7
Tx Power for Modulation Leve
l 8
n HW revision,
unit type and Sub Band.
meter.
Depend o
Tx Power cannot be
higher than the applicable
Maximum Tx Power
para
Cell Extender System Manual
3-12
Summary of Contents for BreezeACCESS II CX
Page 1: ...Cell Extender System Manual August 2004 P N 213837...
Page 2: ...Error No text of specified style in document Cell Extender System Manual ii...
Page 10: ......
Page 12: ......
Page 16: ...Figures Cell Extender System Manual ii...
Page 30: ...Chapter 1 System Description Cell Extender System Manual 1 12...
Page 69: ...A A Appendix A Wiring10 100Base T Jacks...
Page 71: ...B B Appendix B Preparing the Indoor to Outdoor Ethernet Cable...
Page 74: ...Appendix B Preparing the Indoor to Outdoor Ethernet Cable Cell Extender System Manual B 4...