O & C M A N U A L # 8 3 1 1 • T H / I I I F A M I L Y
P G . 1 8
S E C T I O N 6
S E R V I C E
S E C T I O N 6
DISPLAY ERROR CODES
1. "E10"
Oven Fault under
temperature.
2. "E11"
Oven Fault over
temperature.
3. "E21"
Food probe fault over
temperature.
4. "E30"
Slow heating rate.
5. "E31"
Slow cooling rate.
POSSIBLE CAUSE
A. Frozen food product placed in
oven.
B. Air temperature sensor defective.
C. Voltage option incorrect.
A. Heating cable shorted to ground.
B. Air temperature sensor defective.
C. Failed solid state relay.
A. Food probe defective.
A. Oven door open.
B. Door gasket defective or
door out of adjustment.
C. Oven preheat was skipped.
D. Line voltage incorrect, voltage
option on control not pro-
grammed properly.
E. Defective air sensor or product
probe.
F. Defective solid state relay.
G. Bad wire connections or
open heating cable.
A. Failed solid state relay.
B. Defective air temperature sensor.
C. Shorted or grounded
heating cable.
REMEDY
Thaw food prior to placing in oven.
Test air sensor by placing sensor in ice
water bath and using an ohmmeter set on
the ohm scale. The reading should be
approximately 100 ohms resistance. If the
sensor tests out and there are bullet connec-
tors on the leads, cut off bullet connectors,
strip back the insulation 1/2", slide a piece
of heat shrink tubing over the wire, twist the
wires together and solder. Slide the heat
shrink tubing over the soldered connection
and heat in order to shrink material.
Change the voltage setting, referring to the
instructions in Section 6, Service Setup.
Replace heating cable.
Test air sensor using remedy instructions
above for 1B.
Replace solid state relay.
Test food probe by placing in ice water bath
and using an ohmmeter set on the ohm
scale. The reading should be approximate-
ly 100 ohms resistance. If the product
probe tests out and there are bullet connec-
tors on the leads, cut off bullet connectors,
strip back the insulation 1/2", slide a piece
of heat shrink tubing over the wire, twist the
wires together and solder. Slide the heat
shrink tubing over the soldered connection
and heat in order to shrink material.
Close door.
Replace door gasket, adjust door placement,
or replace door.
Return to power-up preheat mode.
Change the voltage setting, referring to the
instructions in Section 6, Service Setup.
Test air sensor using remedy instructions
above for 1B. Test product probe using
remedy instructions above for 3A.
Replace solid state relay.
Check wire connections.
Replace heating cable.
Replace solid state relay.
Test air sensor using remedy instructions
above for 1B.
Replace heating cable.
T R O U B L E S H O O T I N G