Compare Setting
This item is used for compare the feedback of RS232 commands. When the CP8N
send a RS232 command to the controlled device, the device will send back a feedback.
If we add the correct feedback in the data, the CP8N will compare it with the feedback
received from controlled device, to verify the command is work or not. The compare
setting is as the picture below:
1)
The send port must be selected as the same as model setting, otherwise the
event cannot be added. And port 1 cannot be used for compare, for there is no a
receive pin in this port.
2)
User can set the event name; it is optional function, not necessary.
3)
For the events in one event list have priority, from top to bottom, so that the
Enter the compare commands,