CP8N
Programmable Control Panel
All Rights Reserved
Version: CP8N_2016V1.0
User Manual
Page 1: ...CP8N Programmable Control Panel All Rights Reserved Version CP8N_2016V1 0 User Manual...
Page 2: ...ies of the trademark owner No part of this publication may be copied or reproduced without prior written consent FCC Statement This equipment generates uses and can radiate radio frequency energy and...
Page 3: ...in moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may expose...
Page 4: ...el 2 2 2 Side Panel 3 2 3 Rear Panel 4 3 Connections 5 3 1 System Diagram 5 3 2 Connection of Programming and Looping 5 4 System Operations 8 4 1 USB Driver Installation 8 4 2 Software Programming 8 4...
Page 5: ...send the bi direction RS232 and RS485 commands simultaneously to control third party devices Every button can be programmed to send the infrared code control the relay to let them work simultaneously...
Page 6: ...1 Secondly put the device into the hole and adjust it to flush with the table shown in Figure 1 2 Then plug a set screw into the fixing mounting and screw the nuts tightly Figure 1 1 Aperture paper F...
Page 7: ...table please contact the local distributor or reseller for it 2 2 Side Panel Note When use this USB port to program the control panel s buttons the available COM port number should not be more than 10...
Page 8: ...on the setting of PS WP When be used as RS232 it is unidirectional transmission transmit data but without receive b IR1 for control other devices it can be programmable by the PS WP c RS485 the RS485...
Page 9: ...tton can send the RS232 and RS485 commands IR code and control the relay at the same time The demo system diagram as below 3 2 Connection of Programming and Looping CP8N can be connected to the comput...
Page 10: ...Please check the demo picture as below Several CP8Ns Looping connecting After connect the CP8Ns as above and then we should set the ID of each CP8N by PS WP The ID number is from 01 to 99 and it also...
Page 11: ...rol Panel Altimium 7 www altimium com Detailed looping connecting Note Up to 99 CP8Ns can be looped within one system However to achieve normal interaction loop less CP8Ns 10 tops in the system Second...
Page 12: ...n window of PS WP has five parts main menu panel button setting event setting action list and event list In this manual we will take programmable control panels V for example to show the uses of all f...
Page 13: ...imium com panels V and programmable control panels H NOTICE When select the model it will pop up Output Port Selection dialog user can select different RS and IR types depend on the uses of the two sh...
Page 14: ...put mode of PS WP IR1 RS232 1 IR2 RS232 2 IR3 RS232 3 RS485 RS232 1 2 RS232 2 IR2 RS232 1 IR3 IR2 3 3 Connection type the instructions are in the picture below 1 Com connect by serial port 2 USB conne...
Page 15: ...S WP 4 2 2 Panel Key setting There are three different colors of keys in the panel set of PS WP Add a key action to action list then add events to this action make this action will execute the events...
Page 16: ...ctions in the toggle And so on 2 Blue Keys Keys 9 32 all are virtual keys used in the loop function When use the Key Action Type 1 Press Execute events when press button 2 Release Execute events when...
Page 17: ...s in this action Key 35 is delay button there are three time slots can be set See in the picture below The time is counted from the CP8N start When come to time1 the CP8N will execute the events in ti...
Page 18: ...ow you the setting of each event RS232 Setting This item is used for setting the parameters of the CP8N s serial ports Click RS232 it will show as below 1 The data of RS232 can be directly entered or...
Page 19: ...y between times can be set See in picture below 3 The send port must be selected as the same as model setting otherwise the event cannot be added 4 User can set the event name It is optional function...
Page 20: ...e editing and then press OK 2 There are two send types send once and send more times When select more times the send times and the delay between times can be set See in picture below Select a function...
Page 21: ...ere is no I O port in the CP8N so the setting is not introduced in this manual Relay Setting This item is for the replay ports setting The setting is as the picture below Delay setting This item is to...
Page 22: ...he feedback received from controlled device to verify the command is work or not The compare setting is as the picture below 1 The send port must be selected as the same as model setting otherwise the...
Page 23: ...for set the button LEDs in the CP8N to turn on off The setting is as below Page setting White buttons can be set to type page that include four actions To change different actions it will need other w...
Page 24: ...r keys will be added the page event to each of them as below Then set the page event to make four press actions to active the four page number key5 num1 key6 num2 key7 num3 and key8 num4 It will perfo...
Page 25: ...d then button1 the button1 will execute the event of num3 press button1 more times it will execute num3 more times d When press the button8 and then button1 the button1 will execute the event of num4...
Page 26: ...ton1 will execute the event of num2 press button1 more times it will execute num3 then num4 num1 num2 and so on c When press the button7 and then button1 the button1 will execute the event of num3 pre...
Page 27: ...3 x RS232 1 x RS485 3 x Infrared 2 x Relay Serial Control Port RS232 Baud Rate And Protocol 9600 baud 8 data bits 1 stop bit no parity Software PS WP Temperature 20 70 C Frequency Response 20Hz 20KHz...
Page 28: ...ol Panel Altimium 24 www altimium com 6 Panel Drawing CP8N 12 VDC PWR RS232 3 NET IN RS485 RS232 2 NET OUT CONFIG IR USB IR 3 RS232 1 IR 2 IR 1 RELAY 1 RELAY 2 114 mm 70 mm 83 mm 25 mm 3 mm 71 mm 50 m...
Page 29: ...driver is installed correctly and then reconnect the USB cable 3 When uploading the USB cannot be found please restart the software or panel 4 When the LED of a button cannot be lighted please check...
Page 30: ...altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof o...
Page 31: ......
Page 32: ...ALTIMIUM 587 Avenue Blaise Pascal 77550 MOISSY CRAMAYEL T l 01 64 13 31 00 Fax 01 60 29 62 70 Mail contact tesca audio com Web www altimium com...