Troubleshooting/faults/messages
Fault
Cause
Troubleshooting
The machine cannot be
switched on.
The main switch is not
turned on.
Turn the main switch to switch position “I”.
Power failure or phase
failure
Wait for power to be reinstated, or eliminate cause
for loss of power, check factory fuses.
Overload protection
has responded.
Allow motor to cool down, also refer to machine dia-
gnosis display.
Sliding table moved
over saw blade centre
line.
Move the sliding table back to the saw blade centre
line; also refer to machine diagnosis display.
EMERGENCY STOP
button pressed.
Rearm the EMERGENCY STOP button again by
pulling, also refer to machine diagnosis display.
Door in machine frame
or lower base plate in
front of saw blades
opened.
Close the machine door or cover plate; also refer to
machine diagnosis display.
Control circuit fuses
defective
Turn off the main switch, open the switch cabinet
and identify which of the fuses F1, F2, F8 is defec-
tive. Find and eliminate the cause. Replace defec-
tive fuses, only using fuses of the same rating!
The machine switches
off automatically during
operation.
Power failure in one or
several phases due to
responding factory
fuses.
Eliminate cause of phase failure.
Overload protection
has responded due to
blunt saw blade or
excessive feed speed.
Change saw blade or reduce feed speed. Allow
motor to cool down, also refer to machine diagnosis
display.
Control circuit fuses
defective
Turn off the main switch, open the switch cabinet
and identify which of the fuses F1, F2, F8 is defec-
tive. Find and eliminate the cause. Replace defec-
tive fuses, only using fuses of the same rating!
Workpiece jammed
while feeding forward.
Blunt saw blade
Fit a sharp saw blade.
Riving knife thickness
does not match the
saw blade used.
Fit the correct riving knife; it must be thicker than or
equal to the thickness of the main saw blade.
Summary of Contents for ElmoDrive F45
Page 8: ...Identification 8 Identification 0000010040 002 GB EC prototype testing certificate ...
Page 9: ...Identification 9 0000010040 002 GB Identification ...
Page 10: ...Identification 10 Identification 0000010040 002 GB GS test certificate ...
Page 11: ...Identification 11 0000010040 002 GB Identification ...
Page 12: ...Identification 12 Identification 0000010040 002 GB DGUV Test Certificate ...
Page 13: ...Identification 13 0000010040 002 GB Identification ...
Page 14: ...Identification 14 Identification 0000010040 002 GB C US Certificate ...
Page 39: ...Definitions 39 0000010040 002 GB Definitions ...
Page 116: ...Operating 116 Operating 0000010040 002 GB Fig 6 32 ELMO II start screen ...
Page 147: ...Operating 147 0000010040 002 GB Operating Fig 6 68 Switches for saw drives ...
Page 152: ...Operating 152 Operating 0000010040 002 GB 6 4 10 Menu Fig 6 72 Main menu ...