Faults/problems/troubleshooting
256
Faults/problems/troubleshooting
0000010040-002- GB
E53
Brake unit fault: Mains contactor
not in neutral position.
Request a service technician to perform a
repair.
E54
Operating error, incorrect riving
knife position or speed setting, e.g.
too fast for 450 mm saw blade. Dri-
ves cannot be started!
Check rotational speed and riving knife posi-
tion.
E55
Brake unit fault: Communication
problem with machine control unit -
brake unit is operating in default
mode, 450 mm saw blade / 4000
rpm.
Request a service technician to check the
function.
E56
Frequency converter phase failure/
overvoltage
Press any button on the control unit.
E57
Frequency converter excessive
speed
Restart the machine.
If this does not remedy the fault, request a
service technician.
E58
Frequency converter communica-
tion fault
Request a service technician to check the
function.
E59
Emergency running block 3500 rpm
Switch the main saw blade off and on again.
E61
Malfunction, drive positioning, cur-
rent consumption evaluation
Lubricate the axle
E81
Malfunction, shaft encoder
Evaluation faulty, A/B channel
Request a service technician to check the
function.
E91K
K contact error of the STOP button
If the fault occurs repeatedly, request a ser-
vice technician to check the function.
E92
K-n stop signal missing
Check the AC stop circuit
Request a service technician to check the
function.
E93K
K contact error of the START but-
ton
If the fault occurs repeatedly, request a ser-
vice technician to check the function.
E94
K free signal missing
Request a service technician to check the
function.
E99
Excess temperature of the control
electronics
Switch off machine and allow to cool down
before restarting. If fault occurs again, request
a service technician to check the function.
Tbl. 8-2 Fault messages
Fault message
Cause
Troubleshooting
Summary of Contents for ElmoDrive F45
Page 8: ...Identification 8 Identification 0000010040 002 GB EC prototype testing certificate ...
Page 9: ...Identification 9 0000010040 002 GB Identification ...
Page 10: ...Identification 10 Identification 0000010040 002 GB GS test certificate ...
Page 11: ...Identification 11 0000010040 002 GB Identification ...
Page 12: ...Identification 12 Identification 0000010040 002 GB DGUV Test Certificate ...
Page 13: ...Identification 13 0000010040 002 GB Identification ...
Page 14: ...Identification 14 Identification 0000010040 002 GB C US Certificate ...
Page 39: ...Definitions 39 0000010040 002 GB Definitions ...
Page 116: ...Operating 116 Operating 0000010040 002 GB Fig 6 32 ELMO II start screen ...
Page 147: ...Operating 147 0000010040 002 GB Operating Fig 6 68 Switches for saw drives ...
Page 152: ...Operating 152 Operating 0000010040 002 GB 6 4 10 Menu Fig 6 72 Main menu ...