last revision:
04/06/2021
Project Divison Projet
5
1.
How to Use the Plastic Protector Cap
The valve is covered by a plastic protector cap. It can be used
as a template for setting the depth of the valve in the wall.
The
finished wall can fall anywhere along the side of this plastic
guard (Fig.1).
The rough-in cap will also be used as a template to cut out the
opening on the wall. The pre-determined hole size will facilitate
future maintenance of the valve and will ensure the wall open-
ing to be properly covered by trim.
IMPORTANT: CUT YOUR OPENING ACCORDING THE TEM-
PLATE WE RECOMMAND 4 1/4"x2 3/4" PLUS THE OPENING
FOR DIVERTER
The plastic protector cap should be in place until trim is installed
(Fig.2). Please refer to trim kit installation manual for instruc-
tions on how to remove the plug and to install the cartridge .
Comment utiliser le capuchon protecteur
La valve est recouverte d'un capuchon protecteur en plastique.
Il peut être utilisé comme gabarit pour déterminer la bonne
profondeur de la valve dans le mur.
La surface du mur fini doit
absolument demeurer dans l'espace défini par le rebord du
capuchon (Fig.1).
Le capuchon doit aussi servir de gabarit pour découper
l'ouverture dans le mur. La grosseur du trou pré-déterminée fa-
cilitera l'entretien futur de la valve et assurera la couverture du
trou par la garniture de finition.
IMPORTANT: SUIVRE LA FORME DU GABARIT. NOUS RE-
COMMANDONS UNE OUVERTURE PRINCIPALE DE 4 1/4"x2
3/4" SUIVIE D'UNE OUVERTURE POUR LE DÉVIATEUR
Le capuchon protecteur doit demeurer posé jusqu'à l'installation
de la finition (Fig.2). Se référer au guide d'installation de la gar-
niture de finition pour connaître comment retirer le bouchon et
installer la cartouche.
FINISHED WALL STOP
LIMITE DU MUR DE FINITION
INSTALLATION A
Fig.1
Fig. 2
PLUG
BOUCHON