![Alpha AS600M Series Manual Download Page 41](http://html1.mh-extra.com/html/alpha/as600m-series/as600m-series_manual_2905229041.webp)
Chapter 4 Parameter Index
41
Function
code
Parameter name
Setting range
Factory
setting
Modify
flag
Modbus
address
PA.07
leakage
inductance L1 of
motor 1
0.1~2000.0mH
Depend on
model
○
0B07
PA.08
Rotor resistance
R2 of motor 1
0.001~65.000
Ω
○
0B08
PA.09
Mutual
inductance
resistance Lm of
motor 1
0.1~2000.0mH
○
0B09
PA.10
Saturation
coefficient 1 of
motor 1
0.0%~100.0%
○
0B0A
PA.11
Saturation
coefficient 1 of
motor 2
0.0%~100.0%
○
0B0B
PA.12
Saturation
coefficient 3 of
motor 1
0.0%~100.0%
○
0B0C
PA.13
Saturation
coefficient 4 of
motor 1
0.0%~100.0%
○
0C0D
PA.14
Saturation
coefficient 5 of
motor 1
0.0%~100.0%
○
0B0E
PA.15~
PA.28
reserve -
○
0B1C
PA.29
Motor parameter
tuning
0: No operation
1: Static parameter tuning
2: Rotating parameter tuning
0 ×
0B1D
PA.30
Parameter tuning
process
information
-
*
0B1E
Pb: MODBUS Communication
Function
code
Parameter name
Setting range
Factory
setting
Modify
flag
Modbus
address
Pb.00
Baud rate
selection
0: 1200bps 1: 2400bps
2: 4800bps 3: 9600 bps
4: 19200bps 5: 38400bps
3 ×
0C00
Pb.01 Local address
0~31
1
×
0C01
Pb.02
Even-odd check
selection
0: Even parity
1: Odd parity
2: No parity
0 ×
0C02
Summary of Contents for AS600M Series