![Alpha AS600M Series Manual Download Page 34](http://html1.mh-extra.com/html/alpha/as600m-series/as600m-series_manual_2905229034.webp)
Chapter 4 Parameter Index
34
Function
code
Parameter
Setting range
Factory
setting
Modify
flag
Modbus
address
P4.25
AO1 output
range selection
0: 0~10V/0~20mA
1: 2~10V/4~20mA
0
○
0519
P4.26~
P4.27
Reserve -
- -
P4.28 AO1
Gain
-10.00~10.00
1.00
○
051C
P4.29~
P4.30
Reserve -
- -
P4.31 AO1
offset
-100.0%~100.0%
0.0%
×
051F
P5
:
Rigid Tapping and Position Control
Function
Code
Parameter name
Setting Range
Factory
Setting
Modify
Flag
Modbus
address
P5.00
mode of pulse
command
0
:
pulse + Direction signal
1
:
Two-phase pulse (Phase A
+ Phase B)
2
:
CW/CCW
0
×
0600
P5.01
the opposite
direction of
position
command
0
:
not
1
:
Yes
0
×
0601
P5.02
~
P5.03
Reserve
-
-
*
-
P5.04
Rigid tapping
(
position
)
acceleration time
The time from 0 acceleration
to P5.06
0
~
50.00S
0.50
○
0604
P5.05
Rigid tapping
(
position
)
deceleration time
The time from 0 deceleration
to P5.06
0
~
50.00S
0.50
○
0605
P5.06
The max
frequency of
Rigid
tapping(position)
0
~
400.00HZ
30.00HZ
×
0606
P5.07
Rigid tapping
(
position
)
Speed
loop proportional
gain 1
0
~
50.0
3.0
○
0607
P5.08
Rigid tapping
(
position
)
Speed
loop integral time
1
0.000S
~
9.000
0.030
○
0608
P5.09
Rigid tapping
(
position
)
Speed
loop proportional
gain 2
0
~
50.0
5.0
○
0609