Chapter 4 Parameter Index
37
Function
Code
Parameter name
Setting Range
Factory
Setting
Modify
Flag
Modbus
address
P6.28
Orientations
position 3
0
~
a circle of pulse number
-1
0
○
071C
P6.29
Orientations
position 4
0
~
a circle of pulse number
-1
0
○
071D
P6.30
Orientations
position 5
0
~
a circle of pulse number
-1
0
○
071E
P6.31
Orientations
position 6
0
~
a circle of pulse number
-1
0
○
071F
P6.32
Orientations
position 7
0
~
a circle of pulse number
-1
0
○
0720
P6.33
Orientations
position 8
0
~
a circle of pulse number
-1
0
○
0721
P6.34
~
P6.39
Reserve
-
-
*
-
P6.40
Orientation
response constant
0.01
~
10.00
1.00
○
0728
P6.41
A circle of pulse
number
0
~
10000
4096
×
0729
P6.42
Enter zero servo
lock range
0
~
2000
160
○
072A
P6.43
~
P6.44
Reserve
-
-
*
-
P6.45
Orientation
crawling
frequency
0.01
~
3.00HZ
0.10HZ
×
072D
P7
:
Reserve
P8
:
Speed control parameter
Function
Code
Parameter name
Setting Range
Factory
Setting
Modify
Flag
Modbus
address
P8.00
Pre-excitation
current
compensation
amount
0.0~500.0%
100.0% corresponds to the
motor no-load current; the
response time is set in P1.04
The upper limit is 80% of the
rated current of the inverter or
the smaller rated current of
the motor
100.0%
×
0900
P8.01
Speed loop
proportional gain
1
0.1~30.0
3.0
○
0901