Page
35
to
52
Configuring the Tri Power X33 HE
The table below shows all the possible configurations available to better adapt the TRI POWER X33 HE to the
user’s
needs.
CP (Control Panel) =
Indicates that the configuration can be changed from the control panel, as well as from the
configuration software.
SW (Software) =
Indicates that the configuration can be changed from the configuration software only.
FUNCTION
DESCRIPTION
DEFAULT
POSSIBLE CONFIGURATIONS
MOD.
Output frequency
Selects nominal output
frequency
50 Hz
50 Hz
60 Hz
CP
Output Voltage
Selects nominal Output
voltage (Phase / Neutral)
230V
200V *
208V *
220V
230V
240V
CP
220 ÷ 240 in steps of 1V
SW
Operating Mode
Selects one of the 5
operating modes
ON LINE
ON LINE
ECO
SMART ACTIVE
STAND-BY OFF
CP
FREQUENCY CONVERTER
SW
Power off due to
minimum load
Automatically switches off
the TRI POWER X33 HE
in battery operation when
the load is less than 5%
Disabled
Enabled
Disabled
CP
Autonomy
limitation
Sets the maximum time of
battery operation
Disabled
Disabled (complete battery discharge)
1 ÷ 65000 in steps of 1 sec.
SW
Low battery pre-
alarm
Sets the estimated
autonomy time left for low
battery warning
3 min.
1 ÷ 255 in steps of 1 min.
SW
Battery test
Sets the interval of time
for the automatic battery
test
40 hours
Disabled
1 ÷ 1000 in steps of 1 hour
SW
Maximum load
alarm threshold
Selects the user overload
limit
Disabled
Disabled
0 ÷ 103 in steps of 1%
SW
Sound alarm
Selects the operating
mode of the sound alarm
Reduced
Normal
Reduced: does not sound because of
momentary intervention of The bypass
CP
Auxiliary socket
(power share)
Selects the operating
mode of the auxiliary
socket
Always
connected
Always connected
Disconnected after n seconds of
battery operation
Disconnected after n seconds from the
end-of-discharge alarm signal
... (see manual of TRI POWER X33 HE
Tools)
SW
Battery
expansion
Sets the Ah installed
(external battery
extension)
0 Ah
Min.: 0 - Max.: 999
(in steps of 1 unit)
CP
Language
Selects the display
language
English
English
Italian
German
French
Spanish
…………
CP
Date and time
Sets the date and time
--
--
CP