Page
18
to
62
Program
Description
Selectable option
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and low
DC cut-off voltage can be set up
in program 26, 27 and 29.
Pylontech battery
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
WECO battery (only for
48V model)
If selected, programs of 02, 12,
26,
27
and
29
will
be
auto-configured
per
battery
supplier recommended. No need
for further adjustment.
Soltaro battery (only for
48V model)
If selected, programs of 02, 26,
27 and 29 will be automatically
set up. No need for further
setting.
LIb-protocol compatible
battery
Select “LIb” if using Lithium
battery
compatible
to
Lib
protocol. If selected, programs of
02, 26, 27 and 29 will be
automatically set up. No need for
further setting.