background image

4

Subject to change without notice  |  83057200dUK – Translation of the original operating manual |  ait-deutschland GmbH

1.4  Contact

Addresses  for  purchasing  accessories,  for  service 
cases or for answers to questions about the unit and 
this operating manual can be found on the internet at 

DQ\WLPHDQGLVNHSWXSWRGDWH

 

Ɣ

Germany:  www.alpha-innotec.de

 

Ɣ

EU: 

www.alpha-innotec.com

2  Safety

Only  use  the  unit  if  it  is  in  proper  technical  condition 
and  only  use  it  as  intended,  safely  and  aware  of  the 
hazards, and follow this operating manual.

2.1  Intended use

The unit is solely intended for the following functions: 

 

Ɣ

Heating

 

Ɣ 'RPHVWLF

ZDWHU

KHDWLQJ

RSWLRQDO

ZLWK

DFFHVVRULHV

 

Ɣ &RROLQJ RSWLRQDO ZLWK DFFHVVRULHV

or  unit  type 

…K3

 

Ź

Proper use includes complying with the operating 

FRQGLWLRQV

Æ

 “Technical data / Scope of supply”, 

IURP SDJH DQG WKH RSHUDWLQJ PDQXDO DQG

noting and following the reference documents.

 

Ź

When  using  the  local  regulations  note:  laws, 
standards, guidelines, directives.

All other uses of the unit are not as intended.

2.2 

3HUVRQQHOTXDOL¿FDWLRQV

All instructional information in this operating manual is 

VROHO\GLUHFWHGDWTXDOL¿HGVNLOOHGSHUVRQQHO

2QO\ TXDOL¿HG VNLOOHG SHUVRQQHO LV DEOH WR FDUU\ RXW
WKHZRUNRQWKHXQLWVDIHW\DQGFRUUHFWO\,QWHUIHUHQFH
E\ XQTXDOL¿HG SHUVRQQHO FDQ FDXVH OLIHWKUHDWHQLQJ

injuries and damage to property.

 

Ź

Ensure that the personnel is familiar with the  local 
regulations, especially those on safe and hazard-

DZDUHZRUNLQJ

 

Ź 2QO\ DOORZ TXDOL¿HG SHUVRQQHO ZLWK ³HOHFWULFDO´

WUDLQLQJ WR FDUU\ RXW ZRUN RQ WKH HOHFWULFV DQG

electronics.

 

Ź 2QO\ DOORZ TXDOL¿HG VNLOOHG SHUVRQQHO WR GR DQ\

RWKHUZRUNRQWKHV\VWHPHJ

 

Ɣ

Heating installer

 

Ɣ

Plumbing installer

 

Ɣ 5HIULJHUDWLRQ V\VWHP LQVWDOOHU PDLQWHQDQFH

ZRUN

During  the  warranty  and  guarantee  period,  service 

ZRUNDQGUHSDLUVPD\RQO\EHFDUULHGRXWE\SHUVRQQHO

authorised by the manufacturer.

2.3  Personal protective equipment

7KHUHLVDULVNRIFXWWLQJ\RXUKDQGVRQVKDUSHGJHV

of the unit.

 

Ź

Wear  cut-resistant  protective  gloves  during 
transport.

2.4 

5HVLGXDOULVNV

(OHFWULFVKRFN

Components  in  the  unit  are  live  with  life-threatening 
voltage. Before opening the unit panelling:

 

Ź

Disconnect unit from power supply.

 

Ź 3URWHFWXQLWDJDLQVWEHLQJVZLWFKHGEDFNRQDJDLQ

,QMXU\GXHWRÀDPPDEOHOLTXLGVDQGSRWHQWLDOO\

explosive atmospheres

Constituents  of  antifreeze  mixtures,  e.g.  ethanol, 

PHWKDQRODUHKLJKO\ÀDPPDEOHDQGIRUPDQH[SORVLYH

atmosphere:

 

Ź

mix antifreeze in well-ventilated rooms.

 

Ź 1RWH WKH KD]DUGRXV VXEVWDQFH PDUNLQJV DQG

comply with the relevant safety regulations.

Injuries and environmental damage due to 
refrigerant

The  unit  contains  harmful  and  environmentally 

GDQJHURXVUHIULJHUDQW,IUHIULJHUDQWOHDNVIURPWKHXQLW

1. 

6ZLWFKRႇXQLW

2.  Thoroughly ventilate installation room.

3.  Notify authorised customer service.

Summary of Contents for SWC 102H1

Page 1: ...UK 83057200dUK Translation of the original operating manual Operating Manual SWC H1 series Brine Water Heat Pumps...

Page 2: ...1 Remove the front panel of the module box 16 7 2 Heating water quality 16 LOO XVK DQG YHQW KHDW VRXUFH 16 7 4 Vent the circulation pump of the heat source 17 OXVK DQG OO WKH KHDWLQJ DQG domestic hot...

Page 3: ...ating manual of the expansion board DFFHVVRULHV RJERRN LI LQFOXGHG ZLWK WKLV XQLW E WKH manufacturer 8QLW VWLFNHU 7KH XQLW VWLFNHU FRQWDLQV LPSRUWDQW LQIRUPDWLRQ IRU contact with the manufacturer or t...

Page 4: ...IH WKUHDWHQLQJ injuries and damage to property Ensure that the personnel is familiar with the local regulations especially those on safe and hazard DZDUH ZRUNLQJ 2QO DOORZ TXDOL HG SHUVRQQHO ZLWK HOHF...

Page 5: ...m is not planned designed started up and operated according to the given requirements there is D ULVN WKDW WKH IROORZLQJ GDPDJH DQG IDXOWV ZLOO RFFXU Malfunctions and the failure of components e g pum...

Page 6: ...RULHV 2YHU RZ YDOYH 5 Valve motor 6 3 way changeover valve heating circuit domestic hot water 7 Heating circuit hot water circulation pump 8 Module box HLJKW DGMXVWDEOH IRRW Rating plate Rating plates...

Page 7: ...ing the output of the electric heating element RROLQJ SDFNDJH IRU UHWUR WWLQJ XQLWV ZLWK D cooling function 3XPS DVVHPEOLHV IRU VHSDUDWH VWRUDJH WDQN LQWHJUDWLRQ KHDWLQJ FLUFXLW HDWLQJ FLUFXLW VDIHW S...

Page 8: ...RZ ORFDO UHJXODWLRQV Do not open windows with gap tilt open FRQWLQXRXV YHQWLODWLRQ EXW LQVWHDG RSHQ ZLGH IRU D VKRUW WLPH SXUJH YHQWLODWLRQ 4 2 Maintenance Wipe down the outside of the unit only using...

Page 9: ...UDQVSRUW WKH XQLW SUHIHUDEO ZLWK D SDOOHW WUXFN alternatively with a handcart 7UDQVSRUW ZLWK D SDOOHW WUXFN Transport the unit to the place of installation SDFNDJHG DQG VHFXUHG RQ D ZRRGHQ SDOOHW 8QSD...

Page 10: ...many Refrigerant Limit R 134a NJ P R 404A NJ P R 407C NJ P R 410A NJ P Technical data Scope of supply from page 21 Minimum room volume 5HIULJHUDQW FDSDFLW NJ LPLW NJ P NOTE If several heat pumps of th...

Page 11: ...upply DQG SURWHFWHG DJDLQVW EHLQJ VZLWFKHG EDFN RQ again 1 Remove the front panel of the module ER 7 1 Remove the front panel of WKH PRGXOH ER SDJH 2 ORVH VKXW R YDOYHV WR WKH KHDWLQJ FLUFXLW 3 UDLQ W...

Page 12: ...ic connec tions 8 Remove 3 clips on the hydraulic connections 9 Use spanner size SW 37 to unscrew the heating RZ 10 Disconnect the hydraulic connections to do this push the pipes apart as far as neces...

Page 13: ...er pipes due to unacceptable loading Secure all connections against twisting NOTE The heat source can be connected from the top right or left 9 The heat source system has been installed in DFFRUGDQFH...

Page 14: ...t the power supply for the heat pump ZLWK DQ DOO SROH PLQLDWXUH FLUFXLW EUHDNHU ZLWK DW OHDVW PP FRQWDFW VSDFLQJ SHU Note the level of the tripping current Technical data Scope of supply from SDJH Com...

Page 15: ...ol box 1 EXV FDEOH DSSUR P IURP WKH LQJ RI the strain relief at the electrical control box All other cables approx 1 2 m 5 8VH FDEOH WLHV VHSDUDWH SDFN WR WKH 1 EXV FDEOH WR D ZHE RI WKH PDVNLQJ SODWH...

Page 16: ...properties No formation of mineral scale Ideal for closed heating circuits LGHDO S YDOXH GXH WR VHOI DONDOLQLVDWLRQ DIWHU OOLQJ the system I QHFHVVDU VLPSOH DONDOLQLVDWLRQ WR S YDOXH by adding chemic...

Page 17: ...mestic hot water charging circuit 9 Drain pipe of the safety valve is connected 9 The front panel of the module box is unscrewed Ensure that the set pressure of the safety valve is not exceeded 1 3XOO...

Page 18: ...RR 9 6HW WKH RYHU RZ YDOYH NOTE The activities in this section are only nec HVVDU IRU LQ OLQH WDQN LQWHJUDWLRQ RPSOHWH WKH ZRUNVWHSV TXLFNO RWKHUZLVH the maximum return temperature can be exceeded and...

Page 19: ...customer service department In other countries Send notice of completion for KHDW SXPS V VWHPV DQG URXJK FKHFNOLVW WR WKH manufacturer s local partner 4 Arrange for the heat pump system to be commiss...

Page 20: ...PSHG RXW E DS SUR PP 3UHVV WKH UHVHW EXWWRQ EDFN LQ DJDLQ If the safety temperature limiter trips again con tact the local partner of the manufacturer or the factory s customer service 13 Dismantling...

Page 21: ...ox weight with cooling ower weight with cooling kg kg kg kg 0 65 5 65 efrigerant type efrigerant capacity kg 410A 1 05 410A 1 35 Domestic hot water tank Net volume l Impressed current anode integrated...

Page 22: ...weight with cooling ower weight with cooling kg kg kg kg 110 65 115 65 efrigerant type efrigerant capacity kg 410A 1 63 410A 1 84 Domestic hot water tank Net volume l Impressed current anode integrate...

Reviews: