Pull in the cables and conductors and make
the connections
1. Strip the sheathing of all cables to the external
loads before laying in the cable duct of the
control box.
2. Dismantle the cover of the electrical control box:
undo both screws at the front on the switchbox
cover, lift off the cover upwards and from the
rear.
2
1
1 LIN-bus
2
Mains voltage / Sensor
3. Feed the control/sensor cables and unit supply
cable into the housing from the rear.
4. Route cables from underneath through the cable
openings in the control box.
5. Connect cables to the respective terminals
(
“Terminal diagram” on page 35).
Control the controller via a PC
1.
During installation lay a shielded network cable
(category 6) through the unit.
2.
Plug the RJ-45 connector of the network cable
into the socket of the control unit (1).
1
NOTE
The network cable can be retrofitted at any
time.
6.4 Installing the control
NOTE
The control can be inserted in a recess in the
front panel of the unit or can be installed on
the wall.
Insert the control in the unit and connect
1.
If required: Remove masking plate from the
slot. To do this, dismantle the front panel
(
“Dismantle housing panels for transport with
handcart or carrying the unit” on page 9),
press the lugs together and push out of the
openings.
2.
Remove film from the plastic element of the front
panel.
3. Position the control in the recess in the front unit
panel.
4. Cut the cable to length generously so that the
front panel can be removed and placed to the
side of the unit. Do not cut the cable ties for
strain relief of the LIN bus cable on the rear
panel at the electric control box.
–
LIN bus cable approx. 1.1 m from the fixing
of the strain relief at the electrical control box
on the rear panel
–
All other cables approx. 1.2 m