5. Use cable ties (
separate pack) to fix the LIN
bus cable to a web of the masking plate around
20 cm in front of the connector (strain relief).
200 mm
6. Push the cable through the opening in the front
panel of the unit from below and into the control.
7. Press the lugs of the control into the openings in
the front panel of the unit.
Mount the control on the wall and connect
1.
Release the rear bracket from the control: Press
together the lugs on the left and right
2. If visually unattractive: Cut off the lugs on the
rear of the control (are only needed to insert in
the front panel).
3.
Mark 2 drillholes (
“Dimensioned drawing of
control, wall-mounted bracket” on page 28).
4.
If cables are fed in from underneath: Break out
the web at the bottom in the middle of the wall
bracket. Use side-cutters if necessary.
5.
Fix the wall-mounted bracket (2) with 2 wall
plugs (1) and 2 screws (3).
1
2
3
1.
2.
3.
4.
6. Feed in the cables from the wall (e.g. in-wall
box) or from below.
7. Route the LIN bus cable from the top right-hand
side at the rear from the heat pump and plug into
the control at the bottom.
8.
Push the control onto the wall-mounted bracket.
9.
Put on the masking plate on the front panel of
the unit if applicable (accessories).