9
Subject to change without notice | 83059000dUK – Translation of the original operating manual | ait-deutschland GmbH
Cooling
Cooling is integrated in the units. The following options
are possible for the cooling function (
operating
manual of the heating and heat pump controller):
●
Active cooling
●
Control of the cooling function via the heating and
heat pump controller
●
Changeover between heating and cooling
operation
Network connection on the control panel
The control panel can be connected to a computer
or network via a network cable. The heating and
heat pump controller can then be controlled from
the computer or from the network. Furthermore, the
manufacturer's internet-based service can also be
used.
4 Operation and care
NOTE
The unit is operated via the control panel
of the heating and heat pump controller
(
operating manual of the heating and
heat pump controller).
4.1 Energy and environmentally
aware operation
The generally accepted requirements for energy-
aware and environmentally-aware operation of a
heating system also apply to use of a heat pump. The
most important measures include:
●
No unnecessarily high flow temperature
●
No unnecessarily high domestic hot water
temperature (note and follow local regulations)
●
Do not open windows with gap /tilt open
(continuous ventilation), but instead open wide for
a short time (shock ventilation).
●
Make sure that the controller settings are correct
4.2 Maintenance
Wipe down the outside of the unit only using a damp
cloth or cloth with mild cleaning product (washing-up
liquid, neutral cleaning product). Do not use any harsh,
abrasive, acid or chlorine-based cleaning products.
5 Delivery, storage, transport
and installation
ATTENTION
Damage to the housing and the unit components due
to heavy objects.
►
Do not place any objects on the unit which are
heavier than 30 kg.
5.1 Scope of supply
►
Check delivery immediately after receipt for
outwardly visible damage and completeness.
►
Notify supplier of any defects immediately.
The accompanying parts package contains:
Set into the styrofoam component
●
1 supply connection line
28 mm (12 kW) / 22 mm (8 kW)
●
1 return connection line
28 mm (12 kW) / 22 mm (8 kW)
●
3 connection pipes to the heating circuit
●
1 HT-bend DN 40 mm 87°
●
Swelling tape for louvre grille and blind cover
Package 1:
●
1 control panel
●
1 outdoor sensor without cable
●
3 Spax screws 5 x 45
●
3 universal wall/floor anchor 6 x 35
●
2 cable ties 3.5 x 200 mm
Package 2:
●
1 safety valve with manometer
1/2" x 3/4", 3 bar
Package 3:
●
1 double-nipple 1/2"
●
1 T-piece 1/2"
●
2 ball valves DN 25 with filling and emptying
device, with compression-type fitting
●
1 ball valve DN 25 with compression-type fitting
●
1 fill and drain valve