electrical connections
observe the following when performing all work:
Danger!
Danger of fatal injury due to electric
current!
electrical connections may be installed
only by qualified electricians.
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
Danger!
observe the relevant en-, vDe and/or
applicable local safety regulations during
the installation and during all electrical
work.
Comply with technical connection
requirements of the responsible power
supply company (if required by the latter)!
notICe.
all live wires must be stripped before they
are installed in the cable duct of the switch
cabinets!
Hot-water tank
If the heat pump will be used for heating hot water, you
must integrate special hot-water tanks in the heat pump
system. The storage volume must be sufficient so that
the required hot water quantity is available even during
a power outage.
notICe.
the heat exchanger surface of the hot
water tank must be dimensioned so that
the heating capacity of the heat pump is
transferred with minimal spreading.
We offer a variety of hot-water tanks for you to choose
from. They are optimized for use with your heat pump.
notICe.
Integrate the hot-water tank in the
heat pump system corresponding to the
hydraulic diagram for your system.
“Hydraulic connection” instructions.
notICe.
an additional switching valve (accessory)
in the return flow must be mounted in
connection with the multifunction tank.
“Hydraulic connection” instructions.