rinsing, filling and bleeding
the system
CautIon.
the system must be absolutely free from
air before commissioning.
rinse, fill and bleed the heating CirCuit and
hot water buffer tank
To bleed the hot water tank, the heating circuit and hot
water circuit must be rinsed simultaneously.
proCeed as follows for the
LWC 60 -
LWC 100
:
If unit is closed, open bottom front panel…
“Transport with a hand truck”
loosen quick-release screws for the lower front
panel (= control side), remove lower front panel and
set aside…
Rinse and fill unit via the filling and emptying valve…
CautIon.
Do not exceed a pressure of 2.5 bar when
rinsing the unit. the drain line of the
heating circuit safety valve must be closed
before rinsing and filling.
notICe.
rinse heat pump and heating circuit for
about 5 minutes.
lWc 100
1 filling and emptying valve
CautIon.
Make sure to equip the power supply of
the heat pump with a 3-pole automatic
cut-out with at least 3mm contact gap.
Note the level of the release current.
overview “Technical data / scope of delivery”,
“electric” section.
E
D
C
B
www.alpha-innotec.de
D - 95359 Kasendorf
Industriestraße 3
Alpha-InnoTec GmbH
1
1
Ers. d.
Ers. f.
Benennung
Durchflusssensor VFS5-100
603772
-
Zust.
Änderungstext
Datum
9.2.2009
HS
Von
Blatt
von
Werkstoff
Gewicht
-
Maßstab
1:2
Det. Maßstab
Datum
Name
Erstellt
Gepr.
Norm.
9.2.2009
Stenglein
toleranz
Allgemein-
DIN ISO 2768 -c
Oberflächen
ArtikelNr.
---
1
2
3
4
Schutzvermerk nach DIN 34 beachten
Blattformat: A4 hoch
CautIon.
the sensor cable for heat quantity
recording may not be shortened!
notICe.
the control element of the heat and heat
pump regulator can be a connection with
a computer or network using an network
cable designed for such pruposes, thus
allowing the heating and heat pump
regulator to be controlled remotely.
If such a connection is desired, install
a screened network cable (category 6,
with rJ-45 plug) through the unit when
installing the connections and run it
through the front facade of the unit,
parallel to the already-present heating
and heat pump regulator control cable.
close electrical switch cabinet of unit.
Summary of Contents for LWC 100
Page 56: ......