13
We reserve the right to modify technical specifications without prior notice.
UK830504/210627
© Alpha-InnoTec GmbH
Route the sensor wire to the switch cabinet across
the two cable brackets and the transverse rail with
the mounting holes…
proceed in reverse order when installing the
insulation panels and the top side panels. While
doing so, always attach the insulation panel at
the bottom first before using your open hand to
gradually press or pound the panel into place from
the bottom to the top. To facilitate the process,
you can spray on a thin film of soapy water for
lubrication…
CautIon.
the lugs on the insulation panels must
snap into place in the designated areas.
lug:
Snap-in area at the bottom
Snap-in area at the top
the air duCt system 700 (aCCessory)
The air duct system 700 is a complete kit solution for
routing the air flow from the heat pump to the outside
of the house
The kit includes:
1 the wall duct
2 air ducts
3 unit connection (set)
4 weather grille and rain guard
5 screen frames
example drawing of a mounted air duct system:
The air ducts and the wall duct are manufactured from
sturdy materials. The air ducts and the wall duct are
comprised of multiple parts and are interlocking. They
will be delivered in a flat box and are constructed on-
site.
If necessary, they are available in lengths of 450 mm or
1000 mm as well as in angled elbow form.