10
Series AE1L, AE.E, AE.N, AE.H, AE.V, AED1E, AED2N
Design ID, ZD
of a rapid rise in temperature, the gland must be
loosened immediately and the warm-up process
repeated. The leakage can be carried off via the
threaded boring located in the strip tank in the
bearing bracket.
Rule out damages to persons and the environment
through leakage of dangerous substances!
•
Mechanical seal
Non-relieved mechanical seals in all material pairings
and designs are applied. The mechanical seal is
maintenance-free.
In case of heavy leaks due to wear and tear, you
have to exchange the mechanical seal (see disas-
sembly and assembly instructions).
As the running dry of the mechanical
seals must be avoided, the pump
may only be operated in filled state and, if provided,
with activated additional installations (see Chapter
6.1.2).
7.1.2.4 V- belt drive
See our maintenance instructions for V-belt operation
with tensioning device VM 706.0001, Identity No. 133
586.
7.1.2.5 Drive engines and (variable speed gear) drive
See the operating and maintenance instructions by
the manufacturers.