This menu allows a more detailed customization of some parameters. To enter, press and hold the “MENU” key for at least 5
seconds. To change the parameters proceed as indicated for the base menu.
WARNING!
- after 2 minutes of inactivity the control panel automatically exits the menu.
PARAMETER
DESCRIPTION
DEFAULT
CUSTOM
MIN
MAX
UM
1
IAO
Select input device for opening:
0 = disabled
1 = PH1
2 = PH2
3 = S1
4 = S2
0
0
4
2
IAC
Select input device for closing:
0 = disabled
1 = PH1
2 = PH2
3 = S1
4 = S2
5 = PH3/S3
0
0
5
3
IOM
Mode of activation of the opening (
IAO
> 0):
0 = on commitment
1 = on disengagement after commitment
0
0
1
4
ICM
Mode of activation of the closing (
IAC
> 0):
0 = on commitment
1 = on disengagement after commitment
0
0
1
5
PH1
Polarity PH1 input:
0 = NC contact
1 = NO contact
0
0
1
6
PH2
Polarity PH2 input:
0 = NC contact
1 = NO contact
0
0
1
7
S1
Polarity S1 input:
0 = NC contact
1 = NO contact
0
0
1
8
S2
Polarity S2 input:
0 = NC contact
1 = NO contact
0
0
1
9
PS3
Polarity PH3 and S3 inputs:
0 = NC contact
1 = NO contact
0
0
1
10
OLM
Led output management mode in opening movement:
0 = output disabled
1 = LED fixed on and OFF at the end of the movement
2 = LED fixed on and ON at the end of the movement
3 = LED flashes and OFF at end of movement
4 = LED flashes and ON at end of movement
1
0
4
9.9 ADVANCED MENU
Summary of Contents for 12007336
Page 15: ...Italiano 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 51: ...English 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 87: ...Fran ais 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 123: ...Espa ol 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Page 159: ...Nederlandse 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...